1 1/2" Trade Electri Flexible Conduits Corrosion-resistant Plated Steel Type CEA Liquidtight Jacket Zero-Halogen PUR
Where are we? 4 Continents 8 Countries
Got any Questions?
Speak with a real person who will go out of their way to help you!
Call Us: 1-516-482-6313Text Us: 1-516-703-3460
Chat
Live Chat: Bottom Right Corner!
Email Us
info@nassaunationalcable.com
Quick Support
Product Information
Specification
- US Trade Size: 1 1/2"
- ISO: 50 mm
- CSA: 41 mm
- Type: CEA-15
- Minimum Jacket Thickness: 0.040
- Internal Diameter: Min: 1.575 Inches & Max: 1.600 Inches
- Outer Diameter: Min: 1.865 Inches & Max: 1.900 Inches
-
Inside Bend Radius: Static: 4.5 Inches
- Weight: 92.4 Lbs
- Reel 50ft: Part Gray: 888526 & Part Black: 88852
-
Reel 150ft: Part Gray: 888546 & Part Black: 88854
1 1/2" Trade Electri Flexible Conduits Corrosion-resistant Plated Steel Type CEA Liquidtight Jacket Zero-Halogen PUR
Allowable Ampacity for 1 1/2" Trade Electri Flexible Conduits Corrosion-resistant Plated Steel Type CEA Liquidtight Jacket Zero-Halogen PUR : 100 Amps
Application:
- Meets the requirements of Bombardier SMP 800-C for Toxic Gas Generation.
- Meets the requirements of both ASTM E162 for Flame Spread and ASTM E662 for Smoke Generation.
- Mass Transit Vehicles
- Subways and Tunnels
- Enclosed Public Areas
Also Know As:
Electri Flexible Conduits, Liquidtight Jacket, Type CEA , Galvanized Steel, Zero-Halogen, Jacketed Metallic
Combustion & Flammability Properties:
Combustion & Flammability:
- Vertical Burn (Material)
- Vertical Burn (Conduit)
- Oxygen Index %
- Flame Spread Index
- Smoke Generation (Flaming)
- Smoke Generation (Non-Flaming)
- Toxic Gas Generation
- Toxicity Index
Test:
- UL94
- UL360
- D2863
- ASTM E162
- ASTM E662 (NFPA 258)
- ASTM E662 (NFPA 258)
- BOMBARDIER SMP 800-C
- NES 713
Value:
- V-0 Rating; No Flaming Drips
- Pass; No Flaming Drips
- 28.5
- 25; No Flaming Drips
- Ds 41@1.5 Min/Ds 113@4.0 Min
- Ds 4@1.5 Min/Ds 19@4.0 Min
- Pass
- 3.9
Markets:
Healthcare, Oil & Gas Refineries, Rail/Transit, Steel Mills, Utilities
Type CEA
This non-UL liquidtight flexible steel conduit is designed for applications where safety concerns exist regarding a material’s reaction in a fire situation.
Construction:
Inner Core:
- Corrosion-resistant Plated Steel
- 3/8” – 2” Squarelock Profile
- 2-1/2” – 6” Fully Interlocked Profile
- 3/8” – 2” Contain Nylon Cord Packing
Liquidtight Jacket:
- Zero-Halogen Polyurethane
- Resistant to Ozone, Hydrocarbons, Moderate Chemicals and Oils
- Flame Retardant
- Low Smoke
- Low Toxicity
- Sunlight Resistant (UV)
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color