18/24 SHIELDED TRIADS OVERALL SHIELD (STOS) THHN/PVC TC-ER

18/24 SHIELDED TRIADS OVERALL SHIELD (STOS) THHN/PVC TC-ER
Select a Gauge
- 18/1 TRIADS OVERALL SHIELD (TOS) THHN/PVC TC-ER
- 16/1 TRIADS OVERALL SHIELD (TOS) THHN/PVC TC-ER
- 14/1 TRIADS OVERALL SHIELD (TOS) THHN/PVC TC-ER
- 18/2 SHIELDED TRIADS OVERALL SHIELD (STOS) THHN/PVC TC-ER
- 18/4 SHIELDED TRIADS OVERALL SHIELD (STOS) THHN/PVC TC-ER
- 18/8 SHIELDED TRIADS OVERALL SHIELD (STOS) THHN/PVC TC-ER
- 18/12 SHIELDED TRIADS OVERALL SHIELD (STOS) THHN/PVC TC-ER
- 18/16 SHIELDED TRIADS OVERALL SHIELD (STOS) THHN/PVC TC-ER
- 18/36 SHIELDED TRIADS OVERALL SHIELD (STOS) THHN/PVC TC-ER
- 16/2 SHIELDED TRIADS OVERALL SHIELD (STOS) THHN/PVC TC-ER
- 16/4 SHIELDED TRIADS OVERALL SHIELD (STOS) THHN/PVC TC-ER
- 16/8 SHIELDED TRIADS OVERALL SHIELD (STOS) THHN/PVC TC-ER
- 16/16 SHIELDED TRIADS OVERALL SHIELD (STOS) THHN/PVC TC-ER
- 16/12 SHIELDED TRIADS OVERALL SHIELD (STOS) THHN/PVC TC-ER
- 16/24 SHIELDED TRIADS OVERALL SHIELD (STOS) THHN/PVC TC-ER
- 16/36 SHIELDED TRIADS OVERALL SHIELD (STOS) THHN/PVC TC-ER
Availability: In stock
Specification
Gauge | 18 |
---|---|
No. Conductors | 24 |
Stranding | 7/0.0152 |
Insulation Wall, Nom OD Inches | 0.015/0.004 |
O.D. Inches | 1.384 |
New Weight lb/1000FT | 949 Lbs |
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
CONDUCTORS: 18 AWG - 10 AWG Class B stranded bare copper per ASTM B-3 and B-8
INSULATION: Flame-retardant Cross-Linked Polyethylene (XLPE) ICEA Method 1, Table E-2
JACKET: Black sunlight and moisture resistant Polyvinyl Chloride (PVC)
FEATURES:
- Type XHHW-2 conductors
- Rated 90°C wet or dry
- Sunlight and weather resistant
- Excellent abrasion and chemical resistance
- Oil resistant I jacket
APPLICATIONS:
- Constructions of 3 or more conductors are permitted by NEC for TC-ER (exposed run)
- Approved for Class 1 Division 2 hazardous locations per NEC Article 501 (TC)
- Designed for use in conduit, cable tray or direct burial
- Applications include control, power lighting and telemetering where a heat and electrically stable insulation is required
- NEC Article 336 applications
INDUSTRY APPROVALS:
- UL Standard 1277 Type TC-ER
- UL 44 XHHW-2
- IEEE 383 flame test (70,000 btu)
- UL 1685 Flame Test
- ICEA S-95-658 (NEMA WC70)
- NEC Article 336
- EPA 40 CFR, Part 261, Subpart C, heavy metals per Table 1, TCLP method