261-10-8224 Type SP-OS, Type ITC/PLTC, Wire Armored, 24 Shielded Pairs - 20 AWG - 105 Deg. C

261-10-8224 Type SP-OS, Type ITC/PLTC, Wire Armored, 24 Shielded Pairs - 20 AWG - 105 Deg. C
Roll over image to Zoom

261-10-8224 Type SP-OS, Type ITC/PLTC, Wire Armored, 24 Shielded Pairs - 20 AWG - 105 Deg. C

SKU: NNC8743X

Select a Gauge

261-10-8224 Type SP-OS, Type ITC/PLTC, Wire Armored, 24 Shielded Pairs - 20 AWG - 105 Deg. C
Min Length: 1 FT
Max Length: 10000 FT
Price:
Regular price
$0.00 /FT
Sale price
$0.00 /FT
Shipping Cost Calculated at Checkout. Standard Lead Time is 1 to 6 Business Days.
Free Shipping: On orders above $1000
Quantity must be 1 or more

Enter the required footage in the quantity box - Cut to one length

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Chat

Live Chat: Bottom Right Corner!

Email Us

info@nassaunationalcable.com

Product Information

Specification

Specifications

Conductors: Bare soft annealed copper, Class B, 7-strand concentric per ASTM B-8.
Insulation: Flame-retardant Okoseal® (PVC) per UL Standard 13 and 2250, 15 mils nominal thickness, 105°C temperature rating.
Conductor Identification: Pigmented black and white in pairs, black, red and white in triads. Pair or triad assembled with left-hand lay.
Group Shield: Aluminum/Polyester tape overlapped to provide 100% coverage, and a 7-strand tinned copper drain wire, two sizes smaller than the conductor. All group shields are completely isolated from each other.
Communications Wire: 22 AWG, solid, bare copper conductor, 12 mils nominal flame-retardant Okoseal insulation, 105°C rating.
Assembly: Pairs or triads assembled with left hand lay. Fillers included where required to provide a round cable.
Cable Shield: Aluminum/Polyester tape over-lapped to provide 100% coverage, and a 7-strand tinned copper drain wire, same size as the conductor.
Inner Jacket: Black, flame-retardant, low temperature Okoseal per UL 13 and 2250. A rip cord is laid longitudinally under the jacket to facilitate removal.
Wire Armor: A single serving of soft annealed galvanized steel wires applied with a left-hand lay and 90% minimum coverage.
Outer Jacket: Black, flame-retardant, low temperature Okoseal per UL 13 and 2250.
Classifications
: UL Listed as ITC/PLTC - Instrument Tray Cable/Power Limited Tray Cable for use in accordance with Article 727 and Article 725 of the National Electrical Code.
Cables comply with UL 2250 and UL 13 for PLTC, CL2 and CL3.

Applications

Okonite single wire armor (SWA) Type SP-OS (Pair/triad - Individual and Overall Shield) instrumentation cables are designed for use as instrumentation, process control, in ITC non-classified or labeled circuits up to 150 volts and 5 amps (750VA) and in Class 2 or 3 Power-Limited circuits where maximum shielding against external interference is required, as well as shielding among groups, particularly where the cable may be subject to abnormally high current or voltage interference; indoors or outdoors; in wet or dry locations with conductor operating temperatures up to 105°C; in cable trays; in raceways; supported by a messenger wire; under raised floors; for direct burial. Suitable Class I, Division 2, Class II, Division 2, or Class III, Division 2 hazardous locations. Also for use as power-Limited fire protective signaling cable (FPL) per NEC Code 760.
The isolated individual shields over each pair, when properly grounded, prevent crosstalk or capacitive coupling between adjacent pairs which occurs with ac signals, particularly the pulse type.
The overall shield eliminates most of the static interference from the electric field radiated by power cables and other electrical equipment.
The wire armor provides excellent longitudinal strength for use as a messenger cable or for support in vertical drops (NEC Section 300-19) and provides the physical protection against mechanical damage.
For dc service in wet locations X-Olene® insulation is recommended.

Product Features

  • Sunlight resistant.
  • Excellent electromagnetic shielding.
  • Oil resistant.
  • Individual pairs or triads are completely isolated.
  • Maximum noise rejection.
  • Communication wire included in each cable for voice communication during installation or instrument calibration.
  • Excellent longitudinal strength.
  • Lower installed system cost than conduit or EMT systems.
  • Excellent Cut-through resistance.
  • Suitable for IEC/BS application.
  • OSHA Acceptable.

*Data provided on this page is subject to change based on different manufacturers' variances