3/0-3/0-3/0-1/0 BARE CONCENTRIC GROUND SERVICE ENTRANCE CABLE (SER) - CU

3/0-3/0-3/0-1/0 BARE CONCENTRIC GROUND SERVICE ENTRANCE CABLE (SER) - CU

3/0-3/0-3/0-1/0 BARE CONCENTRIC GROUND SERVICE ENTRANCE CABLE (SER) - CU

Write a Review
SKU: NNC2581X

Availability: In stock

Min Length: 1 FT
Max Length: 1000000 FT
Price:
Regular price
$14.49 /FT
Sale price
$14.49/FT
Quantity must be 1 or more

Enter the required footage in the Quantity box

Customer Reviews

Based on 2 reviews
100%
(2)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
S
S.
SER Cable
L
L.H.

Specification

Other Names For 3/0-3/0-3/0-1 Bare Concentric Ground Service Entrance Cable (SER) - CU:

3/0-3/0-3/0-1 Copper SER Service Entrance Cable, 3/0-3/0-3/0-1 Reinforcement Tape Service Entrance Cable, 3/0-3/0-3/0-1 SER Cable, 3/0-3/0-3/0-1 SER Service Cable, 3/0-3/0-3/0-1 Copper Service Cable, 3/0-3/0-3/0-1 Round Service Entrance Cable.

Applications:

SER is a service entrance cable with a reinforcement tape used in all instances where service entrance cables are allowed. The cable is most often used to connect the service drop to the meter base and from the meter base to the distribution panelboard. SER is suitable for wet and dry locations, with temperatures not exceeding 90°C. The voltage rating is 600 volts.

Features:

Conductor:

The cable is equipped with annealed soft copper conductors. It typically has three-phase conductors with a bare neutral.

Insulation:

The cable has cross-linked polyethylene type XHHW-2 insulation.

Jacket:

SE cable is jacketed with gray sunlight-resistant polyvinyl chloride (PVC). This dielectrically strong insulation is resistant to corrosion, abrasion, chemicals, and mechanical impact.

Allowable Ampacity at 60° C: 165

Allowable Ampacity at 75° C: 200

Allowable Ampacity at 90° C: 225

Allowable Ampacity (Dwelling): 225

Specifications:

  • Size AWG: 3/0-3/0-3/0-1
  • Weight per 1,000 ft: 2129 lbs
  • Outside Diameter: 1462 mils
  • Conductors: Annealed Soft Copper
  • Stranding: Phase & Neutral Conductors: 19
  • Stranding: Equipment Ground Conductor: 19
  • Insulation: XLPE
  • Jacket: PVC

Standards:

  • ASTM- All applicable standards
  • UL Standard 44 for XHHW-2 conductors
  • UL Standard 83 for THHN/THWN conductors
  • UL Standard 854
  • Federal Specification A-A-59544
  • National Electrical Code, NFPA 70. 2011 Edition
  • RoHS/ REACH