Alpha Wire 55382 18 AWG 2 Conductor Foil FEP Insulation 300V Xtra Guard 5 Extreme Temperature Cable

Alpha Wire 55382 18 AWG 2 Conductor Foil FEP Insulation 300V Xtra Guard 5 Extreme Temperature Cable
Select a Gauge
- Alpha Wire 55092 24 AWG 2 Conductor Foil FEP Insulation 300V Xtra Guard 5 Extreme Temperature Cable
- Alpha Wire 55093 24 AWG 3 Conductor Foil FEP Insulation 300V Xtra Guard 5 Extreme Temperature Cable
- Alpha Wire 55094 24 AWG 4 Conductor Foil FEP Insulation 300V Xtra Guard 5 Extreme Temperature Cable
- Alpha Wire 55096 24 AWG 6 Conductor Foil FEP Insulation 300V Xtra Guard 5 Extreme Temperature Cable
- Alpha Wire 55099 24 AWG 9 Conductor Foil FEP Insulation 300V Xtra Guard 5 Extreme Temperature Cable
- Alpha Wire 55100/12 24 AWG 12 Conductor Foil FEP Insulation 300V Xtra Guard 5 Extreme Temperature Cable
- Alpha Wire 55192 22 AWG 2 Conductor Foil FEP Insulation 300V Xtra Guard 5 Extreme Temperature Cable
- Alpha Wire 55193 22 AWG 3 Conductor Foil FEP Insulation 300V Xtra Guard 5 Extreme Temperature Cable
- Alpha Wire 55194 22 AWG 4 Conductor Foil FEP Insulation 300V Xtra Guard 5 Extreme Temperature Cable
- Alpha Wire 55196 22 AWG 6 Conductor Foil FEP Insulation 300V Xtra Guard 5 Extreme Temperature Cable
- Alpha Wire 55199 22 AWG 9 Conductor Foil FEP Insulation 300V Xtra Guard 5 Extreme Temperature Cable
- Alpha Wire 55199/12 22 AWG 12 Conductor Foil FEP Insulation 300V Xtra Guard 5 Extreme Temperature Cable
- Alpha Wire 55462 20 AWG 2 Conductor Foil FEP Insulation 300V Xtra Guard 5 Extreme Temperature Cable
- Alpha Wire 55463 20 AWG 3 Conductor Foil FEP Insulation 300V Xtra Guard 5 Extreme Temperature Cable
- Alpha Wire 55464 20 AWG 4 Conductor Foil FEP Insulation 300V Xtra Guard 5 Extreme Temperature Cable
- Alpha Wire 55466 20 AWG 6 Conductor Foil FEP Insulation 300V Xtra Guard 5 Extreme Temperature Cable
- Alpha Wire 55469 20 AWG 9 Conductor Foil FEP Insulation 300V Xtra Guard 5 Extreme Temperature Cable
- Alpha Wire 55470/12 20 AWG 12 Conductor Foil FEP Insulation 300V Xtra Guard 5 Extreme Temperature Cable
- Alpha Wire 55383 18 AWG 3 Conductor Foil FEP Insulation 300V Xtra Guard 5 Extreme Temperature Cable
- Alpha Wire 55384 18 AWG 4 Conductor Foil FEP Insulation 300V Xtra Guard 5 Extreme Temperature Cable
- Alpha Wire 55386 18 AWG 6 Conductor Foil FEP Insulation 300V Xtra Guard 5 Extreme Temperature Cable
- Alpha Wire 55389 18 AWG 9 Conductor Foil FEP Insulation 300V Xtra Guard 5 Extreme Temperature Cable
- Alpha Wire 55390/12 18 AWG 12 Conductor Foil FEP Insulation 300V Xtra Guard 5 Extreme Temperature Cable
- Alpha Wire 55362 16 AWG 2 Conductor Foil FEP Insulation 300V Xtra Guard 5 Extreme Temperature Cable
- Alpha Wire 55363 16 AWG 3 Conductor Foil FEP Insulation 300V Xtra Guard 5 Extreme Temperature Cable
- Alpha Wire 55366 16 AWG 6 Conductor Foil FEP Insulation 300V Xtra Guard 5 Extreme Temperature Cable
- Alpha Wire 55369 16 AWG 9 Conductor Foil FEP Insulation 300V Xtra Guard 5 Extreme Temperature Cable
- Alpha Wire 55370/12 16 AWG 12 Conductor Foil FEP Insulation 300V Xtra Guard 5 Extreme Temperature Cable
Availability: In stock
Specification
Conductor Count | 2 CONDUCTOR |
Conductor Material | TINNED COPPER |
Conductor Size | 18 AWG (AMERICAN WIRE GAUGE) |
Conductor Type | STRANDED CONDUCTOR |
Fire Rating | GENERAL PURPOSE |
Insulation Material | FEP-FLUORINATED ETHYLENE PROPYLENE |
Jacket Material | FEP-FLUORINATED ETHYLENE PROPYLENE |
Applicable Specifications | CA Prop 65, CE, CSA CMP, CSA FT6, UL AWM 20229, UL CMP |
Screen/Shield | YES |
Shield Construction | FOIL SHIELD |
Voltage | 300V |
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
Alpha Wire Xtra-Guard® 5 (Temperature/Chemical Resistant FEP Jacket)
- Extreme-performance cable featuring FEP insulation and jacketing for reliable performance in temperatures from -80°C to +200°C.
- Suitable for use in Class 1 cleanrooms and recognized by the FDA, when sterilized, for food and medical-grade applications.
- Impervious to oils, solvents, chemicals, fuels, and acids.
- Provides exceptional protection against EMI when Supra-Shield is specified.
Features
• The preferred cable for unsurpassed maximum temperature and chemical performance
• Temperature range from -80°C to +200°C
• UL, CSA listed
• 100% impervious to all chemicals, solvents, acids, fuels, and water
• Suitable for Class 1 cleanrooms
• FDA food/medical grade (sterilizable)
• Low-friction FEP jacket for easy routing
• Fast, easy stripping of insulation and jacket
• Colour-coded, tinned copper conductors
• 300 V
• Unshielded, foil shielded, or Supra-Shield® foil/braid
• Outstanding ultraviolet light stability in all jacket colours
• Aramid fibre ripcord for easy jacket stripping
• Excellent flame resistance and low smoke generation: Passes NFPA 262-2007
Applications
• Food and beverage wash-down
• Cleanroom environments
• Food/medical-grade applications
• Turbine generators
• Chemical processing
• Military electronics
• Mining instrumentation
FIT® Tubing Recommendations
• FIT-650: Chemical/temperature resistant flexible fluoroelastomer
• FIT-400: Temperature/chemical resistant FEP
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.