Okotherm CIC Fire Resistant Cable - Nickel Copper

Okotherm CIC Fire Resistant Cable - Nickel Copper

Okotherm CIC Fire Resistant Cable - Nickel Copper

SKU: NNC7693X
  Product Name Length Price (Per FT.) Action
Product Name

546-15-3403 Okotherm CIC Fire Resistant Cable - Nickel Copper - 14 AWG

Length
/FT
Price (Per FT.)
Call 516-482-6314 for pricing
Action

Product Name

546-15-3503 Okotherm CIC Fire Resistant Cable - Nickel Copper - 12 AWG

Length
/FT
Price (Per FT.)
Call 516-482-6314 for pricing
Action

Product Name

546-15-3603 Okotherm CIC Fire Resistant Cable - Nickel Copper - 10 AWG

Length
/FT
Price (Per FT.)
Call 516-482-6314 for pricing
Action

Product Name

571-15-3553 Okotherm CIC Fire Resistant Cable - Nickel Copper - 8 AWG

Length
/FT
Price (Per FT.)
Call 516-482-6314 for pricing
Action

Product Name

571-15-3753 Okotherm CIC Fire Resistant Cable - Nickel Copper - 4 AWG

Length
/FT
Price (Per FT.)
Call 516-482-6314 for pricing
Action

Specification

Applications
Okotherm CIC 600 volt power cables are used in systems where, in the event of a fire, circuit integrity is required in order to maintain a process or to safely shut down the process. Fire resistance is determined by compliance to the IEC 60331 circuit integrity fire test. Okotherm CIC cables maintain circuit integrity based on qualification to the IEC standard 60331 for all temperatures and times up to and including 2000°F for three hours. When exposed to a fire, the Okotherm CIC insulation becomes an electrically insulating ceramic-like ash that is capable of maintaining the operating voltage.
Okotherm CIC CLX Type MC-HL cables with the impervious, continuous aluminum corrugated sheath are recommended as an alternative to a wire conduit system. These cables may be installed indoors or outdoors, in wet or dry locations, as open runs of cable secured to supports not more than six feet apart, in cable tray, as an aerial cable on a messenger, in any approved raceway, direct burial, or encased in concrete. They are also approved for use in Class I & II, Division 1 and 2, Class III, Division 1 and 2 and Class I, Zones1&2 hazardous locations per NEC Articles 501, 502, 503, and 505.
Okotherm CIC CLX Type MC-HL power cables are authorized for use on services, feeders and branch circuits for power, lighting, control and signaling circuits in accordance with NEC articles 330 and 725.


*Data provided on this page is subject to change based on different manufacturers' variances

** Images are for display purposes only refer to Product Technical Details for accurate information on the product.