OLFLEX Classic 100 Cable 3 G 2.5 Core mm² W/ GN-YE Protective Conductor BK 0,6/1 kV

OLFLEX Classic 100 Cable 3 G 2.5 Core mm² W/ GN-YE Protective Conductor BK 0,6/1 kV
Select a Gauge
- OLFLEX Classic 100 Cable 3 G 1.0 Core mm² W/ GN-YE Protective Conductor BK 0,6/1 kV
- OLFLEX Classic 100 Cable 5 G 1.0 Core mm² W/ GN-YE Protective Conductor BK 0,6/1 kV
- OLFLEX Classic 100 Cable 2 X 1.5 Core mm² W/O Protective Conductor BK 0,6/1 kV
- OLFLEX Classic 100 Cable 3 G 1.5 Core mm² W/ GN-YE Protective Conductor BK 0,6/1 kV
- OLFLEX Classic 100 Cable 4 G 1.5 Core mm² W/ GN-YE Protective Conductor BK 0,6/1 kV
- OLFLEX Classic 100 Cable 5 G 1.5 Core mm² W/ GN-YE Protective Conductor BK 0,6/1 kV
- OLFLEX Classic 100 Cable 4 G 2.5 Core mm² W/ GN-YE Protective Conductor BK 0,6/1 kV
- OLFLEX Classic 100 Cable 4 G 4.0 Core mm² W/ GN-YE Protective Conductor BK 0,6/1 kV
- OLFLEX Classic 100 Cable 4 G 6.0 Core mm² W/ GN-YE Protective Conductor BK 0,6/1 kV
Availability: In stock
Specification
Number of Cores and mm² per Conductor: 3 G 2.5
Outer diameter: 0.4448 Inches
Copper index: 0.0483 Lbs
Weight: 0.1222 Lbs
Article number: 1120469
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
Benefits:
• High electrical performance due to 4 kV test voltage
Application range:
• Plant engineering
• Industrial machinery
• Heating and air-conditioning systems
• Power stations
• Stage applications
• For fixed installation as well as occasional flexing at free, non-continuously recurring movement without tensile load
• Suitable for torsional applications which are typical for the loop in wind turbine generators (WTG)
• Suitable for outdoor applications
• Each dimension with nominal/ minimum average wall thickness of the outer sheath of at least 1.8 mm: For applications where a
• strengthened outer sheath may turn out to be advantageous
Product features
• Flame-retardant according IEC 60332-1-2
• UV and weather-resistant according to ISO 4892-2
• Ozone-resistant according to EN 50396
• Flexible down to -30°C
Product Make-up
• Fine-wire strand made of bare copper wires
• Core insulation: PVC, cold-resistant
• PVC outer sheath, cold-resistant, black (RAL 9005)
Technical Data:
• Classification ETIM 5: ETIM 5.0 Class-ID: EC000057
ETIM 5.0 Class-Description: Low voltage power cable
• Classification ETIM 6: ETIM 6.0 Class-ID: EC000057
ETIM 6.0 Class-Description: Low voltage power cable
• Core identification code: Up to 5 cores: colour-coded according to VDE 0293-308, refer to Appendix T9
From 6 cores: ÖLFLEX® colour code, refer to Appendix T7
• Conductor stranding: Fine wire according to VDE 0295, class 5/IEC 60228 class 5
• Torsion movement in WTG: TW-0 & TW-1, refer to Appendix T0
• Minimum bending radius: Occasional flexing: 15 x outer diameter
Fixed installation: 4 x outer diameter
• Nominal voltage: U0/U: 600/1000 V
• Test voltage: 4000 V
• Protective conductor: G = with GN-YE protective conductor
X = without protective conductor
• Temperature range: Occasional flexing: -30°C to +70°C
Fixed installation: -40°C to +80°C
*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
Video