OLFLEX Classic 110 Cable 16 G 0.75 Core mm² W/ GN-YE Protective Conductor PVC Control

OLFLEX Classic 110 Cable 16 G 0.75 Core mm² W/ GN-YE Protective Conductor PVC Control

OLFLEX Classic 110 Cable 16 G 0.75 Core mm² W/ GN-YE Protective Conductor PVC Control

SKU: NNC28252X

Select a Gauge

OLFLEX Classic 110 Cable 16 G 0.75 Core mm² W/ GN-YE Protective Conductor PVC Control

Availability: In stock

Min Length: 1 FT
Max Length: 1000000 FT
Price:
Quantity must be 1 or more

Enter the required footage in the Quantity box

Specification

Number of Cores and mm² per Conductor: 16 G 0.75
Outer diameter: 0.4370 Inches
Copper index: 0.0774 Lbs
Weight: 0.1478 Lbs
Article number: 1119116

[/short

Benefits:

• Wide choice of standardized lengths and individual cuts
• Very broad range, items with up to 100 conductors

Application range:

• For fixed installation as well as occasional flexing at free, non-continuously recurring movement without tensile load
• Dry or damp rooms that are subject to medium mechanical loads
• Suitable for torsional applications which are typical for the loop in wind turbine generators (WTG)
• In power chains for a travelling distance up to 5 m and 0,2 ... 1 million bending cycles, for following dimensions: 0,5 to 2.5mm²
and 2 to 7 conductors

Product features:

• Flame-retardant according IEC 60332-1-2
• Good chemical resistance, see catalogue appendix T1
• Oil-resistant according to DIN EN 50290-2-22 (TM54)

Norm references / Approvals:

• VDE reg. no. 7030 for the following sizes:
• up to 2.5 mm²: 2 - 65 cores
• from 4 mm²: 2 - 7 cores
• from 25 mm²: 2 - 5 cores

Product Make-up:

• Fine-wire strand made of bare copper wires
• PVC insulation LAPP P8/1
• Cores twisted in layers
• PVC outer sheath, grey (similar RAL 7001)

Technical Data:

• Classification ETIM 5: ETIM 5.0 Class-ID: EC000104
                                             ETIM 5.0 Class-Description: Control cable

• Classification ETIM 6: ETIM 6.0 Class-ID: EC000104
                                             ETIM 6.0 Class-Description: Control cable

• Core identification code: Black with white numbers acc. to VDE 0293-1

• Conductor stranding: Fine wire according to DIN EN 60228 (VDE 0295), class 5 / IEC 60228 class 5

• Torsion movement in WTG: TW-0 & TW-1, refer to Appendix T0

• Minimum bending radius: Occasional flexing: 10 x outer diameter
                                                    In power chains: 15 x outer diameter
                                                    Fixed installation: 4 x outer diameter

• Nominal voltage: U0/U: 300/500 V

• Test voltage: 4000 V

• Protective conductor: G = with GN-YE protective conductor
                                             X = without protective conductor

• Temperature range: Occasional flexing: -15°C to +70°C
                                         In power chains: -5°C to +70°C
                                         Fixed installation: -40°C to +80°C