CATHODIC PROTECTION CABLE HMWPE 75C 600V COPPER CABLE

CATHODIC PROTECTION CABLE HMWPE 75C 600V COPPER CABLE
Specification

Cathodic Protection Cable HMWPE 75c 600v Copper Cable

Applications:
Cathodic Protection Cable is used for direct earth burial DC feeder cable for cathodic protection systems, storage tanks, pipelines, wells, ocean vessels, and metallic structures buried or water submerged.

Standards:
2.1 ASTM B-1, B-3, B-8, B-33, B-172,and B-173 for soft drawn annealed copper conductors 2.2 ASTM D-1248, NEMA WC-5, ICEA S-61-402 for High Molecular Weight Polyethylene (HMWPE). 2.3 UL 83, UL 1581 and UL 2556

Conductors:
Single stranded copper conductors per UL83 and ASTM requirements. 

Insulation:
The conductor shall be insulated with black, sunlight resistant polyethylene complying with the physical and electrical properties per ASTM D-1248, Type I, Class A thru D, Cat 4, and Grades E4-E5. Types II, III, and IV are available on request. The insulation shall be concentrically applied and the minimum at any point shall not be less than 90% of the specified average thickness. Rated at 75°C, 600 volts. 

*Data provided on this page is subject to change based on different manufacturers variances.

Specification

Cathodic Protection Cable HMWPE 75c 600v Copper Cable

Applications:
Cathodic Protection Cable is used for direct earth burial DC feeder cable for cathodic protection systems, storage tanks, pipelines, wells, ocean vessels, and metallic structures buried or water submerged.

Standards:
2.1 ASTM B-1, B-3, B-8, B-33, B-172,and B-173 for soft drawn annealed copper conductors 2.2 ASTM D-1248, NEMA WC-5, ICEA S-61-402 for High Molecular Weight Polyethylene (HMWPE). 2.3 UL 83, UL 1581 and UL 2556

Conductors:
Single stranded copper conductors per UL83 and ASTM requirements. 

Insulation:
The conductor shall be insulated with black, sunlight resistant polyethylene complying with the physical and electrical properties per ASTM D-1248, Type I, Class A thru D, Cat 4, and Grades E4-E5. Types II, III, and IV are available on request. The insulation shall be concentrically applied and the minimum at any point shall not be less than 90% of the specified average thickness. Rated at 75°C, 600 volts. 

*Data provided on this page is subject to change based on different manufacturers variances.

Details

Applications:
Cathodic Protection Cable is used for direct earth burial DC feeder cable for cathodic protection systems, storage tanks, pipelines, wells, ocean vessels, and metallic structures buried or water submerged.

Standards:
2.1 ASTM B-1, B-3, B-8, B-33, B-172,and B-173 for soft drawn annealed copper conductors 2.2 ASTM D-1248, NEMA WC-5, ICEA S-61-402 for High Molecular Weight Polyethylene (HMWPE). 2.3 UL 83, UL 1581 and UL 2556

Conductors:
Single stranded copper conductors per UL83 and ASTM requirements. 

Insulation:
The conductor shall be insulated with black, sunlight resistant polyethylene complying with the physical and electrical properties per ASTM D-1248, Type I, Class A thru D, Cat 4, and Grades E4-E5. Types II, III, and IV are available on request. The insulation shall be concentrically applied and the minimum at any point shall not be less than 90% of the specified average thickness. Rated at 75°C, 600 volts. 

*Data provided on this page is subject to change based on different manufacturers variances.

Video

Write Your Own Review

You're reviewing: CATHODIC PROTECTION CABLE HMWPE 75C 600V COPPER CABLE

How do you rate this product? *

 
1 1 star
2 2 star
3 3 star
4 4 star
5 5 star
Price
Value
Quality
CATHODIC PROTECTION CABLE HMWPE 75C 600V COPPER CABLE