TELCOFLEX II CENTRAL OFFICE POWER WIRE

TELCOFLEX II CENTRAL OFFICE POWER WIRE
Specification

TelcoFlex® II Central Office Power Wire products at the best prices you'll find anywhere. These cables posess superior flexibility and durability, which makes them ideal for applications which require cable pulling through tray systems. TelcoFlex® II Central Office Power Wire and Cable Class I Flexible Tinned Strand Without Braid. The Cable has low-smoke, lead-free and silicone-free non-halogenated insulation. UL Central Office Power Cable 105ºC dry, 60ºC wet. UL Listed RHH/LS FT4 and VW-1, 90ºC dry, 60ºC wet, 600 volts. Sizes 1/0 and larger are UL, CT USE rated. CSA AWM I B 105ºC, 600 volts.

  Product Name
Length
Price (Per FT.)
 
TELCOFLEX II CENTRAL OFFICE POWER WIRE

8 AWG TELCOFLEX II KS24194 L2 CENTRAL OFFICE POWER WIRE

Size: 8 AWG
Conductor Strand: 41/.0201
Insulation Thickness: 0.060 inches
Outside Diameter: 0.274 inches
Weight: 0.086 lbs per ft
Max. D.C. Res. @ 20ºC: .6790

FT.
$1.18

TELCOFLEX II CENTRAL OFFICE POWER WIRE

6 AWG TELCOFLEX II KS24194 L2 CENTRAL OFFICE POWER WIRE

Size: 6 AWG
Conductor Strand: 65/.0201
Insulation Thickness: 0.060 inches
Outside Diameter: 0.315 inches
Weight: 0.12 lbs per ft
Max. D.C. Res. @ 20ºC: .4360

FT.
$1.37

TELCOFLEX II CENTRAL OFFICE POWER WIRE

4 AWG TELCOFLEX II KS24194 L2 CENTRAL OFFICE POWER WIRE

Size: 4 AWG
Conductor Strand: 105/.0201
Insulation Thickness: 0.060 inches
Outside Diameter: 0.385 inches
Weight: 0.193 lbs per ft
Max. D.C. Res. @ 20ºC: .2740

FT.
$2.05

TELCOFLEX II CENTRAL OFFICE POWER WIRE

2 AWG TELCOFLEX II KS24194 L2 CENTRAL OFFICE POWER WIRE

Size: 2 AWG
Conductor Strand: 168/.0201
Insulation Thickness: 0.060 inches
Outside Diameter: 0.430 inches
Weight: 0.284 lbs per ft
Max. D.C. Res. @ 20ºC: .1720

FT.
$3.02

TELCOFLEX II CENTRAL OFFICE POWER WIRE

1/0 AWG TELCOFLEX II KS24194 L2 CENTRAL OFFICE POWER WIRE

Size: 1/0 AWG
Conductor Strand: 266/.0201
Insulation Thickness: 0.080 inches
Outside Diameter: 0.560 inches
Weight: 0.457 lbs per ft
Max. D.C. Res. @ 20ºC: .1090

FT.
$4.14

TELCOFLEX II CENTRAL OFFICE POWER WIRE

2/0 AWG TELCOFLEX II KS24194 L2 CENTRAL OFFICE POWER WIRE

Size: 2/0 AWG
Conductor Strand: 342/.0201
Insulation Thickness: 0.080 inches
Outside Diameter: 0.620 inches
Weight: 0.57 lbs per ft
Max. D.C. Res. @ 20ºC: .0868

FT.
$5.01

TELCOFLEX II CENTRAL OFFICE POWER WIRE

4/0 AWG TELCOFLEX II KS24194 L2 CENTRAL OFFICE POWER WIRE

Size: 4/0 AWG
Conductor Strand: 532/.0201
Insulation Thickness: 0.080 inches
Outside Diameter: 0.745 inches
Weight: 0.844 lbs per ft
Max. D.C. Res. @ 20ºC: .0546

FT.
$7.19

TELCOFLEX II CENTRAL OFFICE POWER WIRE

350 MCM TELCOFLEX II KS24194 L2 CENTRAL OFFICE POWER WIRE

Size: 350 MCM
Conductor Strand: 888/.0201
Insulation Thickness: 0.095 inches
Outside Diameter: 0.960 inches
Weight: 1.336 lbs per ft
Max. D.C. Res. @ 20ºC: .0334

FT.
$10.62

TELCOFLEX II CENTRAL OFFICE POWER WIRE

500 MCM TELCOFLEX II KS24194 L2 CENTRAL OFFICE POWER WIRE

Size: 500 MCM
Conductor Strand: 1221/.0201
Insulation Thickness: 0.095 inches
Outside Diameter: 1.090 inches
Weight: 1.85 lbs per ft
Max. D.C. Res. @ 20ºC: .0234

FT.
$14.93

TELCOFLEX II CENTRAL OFFICE POWER WIRE

750 MCM TELCOFLEX II KS24194 L2 CENTRAL OFFICE POWER WIRE

Size: 750 MCM
Conductor Strand: 1850/.0201
Insulation Thickness: 0.110 inches
Outside Diameter: 1.314 inches
Weight: 2.74 lbs per ft
Max. D.C. Res. @ 20ºC: .0157

FT.
$21.41

Specification

TelcoFlex® II Central Office Power Wire products at the best prices you'll find anywhere. These cables posess superior flexibility and durability, which makes them ideal for applications which require cable pulling through tray systems. TelcoFlex® II Central Office Power Wire and Cable Class I Flexible Tinned Strand Without Braid. The Cable has low-smoke, lead-free and silicone-free non-halogenated insulation. UL Central Office Power Cable 105ºC dry, 60ºC wet. UL Listed RHH/LS FT4 and VW-1, 90ºC dry, 60ºC wet, 600 volts. Sizes 1/0 and larger are UL, CT USE rated. CSA AWM I B 105ºC, 600 volts.

Details

Applications:
TelcoFlex® II Central Office Power Wire and Cable Class I Flexible Tinned Strand Without Braid. The Cable has low-smoke, lead-free and silicone-free non-halogenated insulation. UL Central Office Power Cable 105ºC dry, 60ºC wet. UL Listed RHH/LS FT4 and VW-1, 90ºC dry, 60ºC wet, 600 volts. Sizes 1/0 and larger are UL, CT USE rated. CSA AWM I B 105ºC, 600 volts.

Specifications:
Meets or exceeds the following:
UL Listed As: Central Office Power Cable
UL Listed Standard 44: Thermoset Insulated Type RHH/ST1
FT-4 Flame Test
VW-1
ASTM B-33 and B172 for Flexible Strand
Physical and Electrical tests in accordance with UL Standard 44 Requirements
CSA AWM I B 105ºC
GR - 347 - Core Compliant by Telcordia
Meets the Requirements of WP93811 for Cold Flow (Creep) and Cut Through
Non-Halogen
Low Smoke - LS
IEC 60674 and 60332
RoHS / Reach Compliant

Construction:
Southwire's TelcoFlex ® II Cable is single conductor with a class I (modified) bunched (8 and 6 AWG) and rope-bunched (4 AWG and larger) stranded tinned copper conforming to ASTM B-33 and Underwriter's Laboratories requirements. An opaque mylar tape shall be applied over the conductor to facilitate stripping. Insulation is 90ºC rated low smoke, non-halogen, TelcoHyde™ 5221 conforming to Underwriter's Laboratories Standard 44 and Telcordia Specification GR-347-CORE, also UL and CSA 105ºC AWM rated. The insulation has a limiting oxygen index of 35%.

Conductors:
Class I modified bunched (8 and 6 AWG) or rope-bunched (4 AWG and larger) stranded tin-coated copper conforming to ASTM B-33 and Underwriters' Laboratories Requirements. An opaque mylar tape shall be applied over the conductor to facilitate stripping.

Insulation:
90ºC / 105ºC rated low smoke, non-halogen TelcoHyde™ 5221 conforming to Underwriters' Laboratories Standard 44, Subjects 509 and 758, and CSA C22.2 No. 210.2 M90. In addition, TelcoHyde™ 5221 complies with the requirements of Telcordia Specification GR-347-CORE. The insulation has a limiting oxygen index of 35%.

Surface Marking:
Two sides of the cable shall be printed using an ink of a contrasting color and with the following information: "SOUTHWIRE TELCOFLEX (R) II/ KS24194 (TM) L2 NON-HAL (UL) E18321 _ AWG 600 VOLTS RHH ST1 FT4 OR AWM 3578 60(D)C WET VW-1 --- LL8825 CSA AWM I B 105(D)C 600 VOLTS FT4-ST1 YEAR TIME JULIAN DATE --- MEETS IEC INCLUDING 60674 & 60332 SEQUENTIAL FOOTAGE MARKS"
Add "FOR CT USE" before "(UL)" on Sizes 1/0 AWG and larger. Sequential footage markings shall be applied at 2 foot intervals on one side of the cable. "SOUTHWIRE manufacturing order number.