INDUSTRIAL SINGLE PAIR TYPE EX OVERALL SHIELDED THERMOCOUPLE EXTENSION CABLE

INDUSTRIAL SINGLE PAIR TYPE EX OVERALL SHIELDED THERMOCOUPLE EXTENSION CABLE
Specification

APPLICATION:
Superior flame-retardant cable for use in thermocouple extension applications in caustic environments where protection from electrostatic interference is required. UL listed as Type TC and approved for installation indoors or outdoors, aerially, in conduits, ducts and cable trays. May be installed at temperatures as low as -35°C and used in NEC Class 1, Division 2 hazardous locations.

CONDUCTORS:
Annealed, solid thermocouple extension grade alloys calibrated to standard limits of error per ANSI-MC96.1

INSULATION:
Flame-retardant ethylene propylene rubber (FR-EP) color coded per ANSI-MC96.1. Flame-retardant cross-linked polyethylene per ICEA S-66-524

INDIVIDUAL SHIELD:
Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire

COMMUNICATION WIRE:
Multipair constructions contain a bare copper orange PVC-insulated communication wire

OVERALL SHIELD:
Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire

JACKET:
Sunlight-resistant chlorinated polyethylene (CPE) color coded per ANSI-MC96.1. A ripcord is applied longitudinally under the jacket to facilitate stripping

FLAME TESTS:
• IEEE 383 (70,000 BTU/hr) Flame Test
• IEEE 1202 (70,000 BTU/hr)
• UL Standard 13 (70,000 BTU/hr) Flame Test
• CSA FT4 Flame Test

  Product Name
Length
Price (Per FT.)
 
INDUSTRIAL SINGLE PAIR TYPE EX OVERALL SHIELDED THERMOCOUPLE EXTENSION CABLE

16 AWG 1 PAIR TYPE EX OVERALL SHIELDED THERMOCOUPLE EXTENSION CABLE

FT.
Call 516-472-0650 for pricing

Specification

APPLICATION:
Superior flame-retardant cable for use in thermocouple extension applications in caustic environments where protection from electrostatic interference is required. UL listed as Type TC and approved for installation indoors or outdoors, aerially, in conduits, ducts and cable trays. May be installed at temperatures as low as -35°C and used in NEC Class 1, Division 2 hazardous locations.

CONDUCTORS:
Annealed, solid thermocouple extension grade alloys calibrated to standard limits of error per ANSI-MC96.1

INSULATION:
Flame-retardant ethylene propylene rubber (FR-EP) color coded per ANSI-MC96.1. Flame-retardant cross-linked polyethylene per ICEA S-66-524

INDIVIDUAL SHIELD:
Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire

COMMUNICATION WIRE:
Multipair constructions contain a bare copper orange PVC-insulated communication wire

OVERALL SHIELD:
Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire

JACKET:
Sunlight-resistant chlorinated polyethylene (CPE) color coded per ANSI-MC96.1. A ripcord is applied longitudinally under the jacket to facilitate stripping

FLAME TESTS:
• IEEE 383 (70,000 BTU/hr) Flame Test
• IEEE 1202 (70,000 BTU/hr)
• UL Standard 13 (70,000 BTU/hr) Flame Test
• CSA FT4 Flame Test

Details

Industrial Single Pair Type EX Overall Shield

High temperature conditions calls for Type EX Thermocouple Cable, which is designed with an operational temperature at 105 degrees Celsius and a cold bend of -350C. The cable is insulated with a flame retardant EPR and double shielded with an aluminum tape. It is jacketed with a color coded Chlorinated Polyethylene for maximum performance.

• Conductor

It measures 16 AWG with a conductor thickness of approximately 0.150 inches. Copper is a good electrical conductor and will ensure you a superb electrical transmission in your wiring system. Annealing improves the flexibility of the copper conductors making them soft.

• Compliance

i. ANSI-MC96.1
ii. ICEA S-66-524
iii. IEEE 383 flame test
iv. CSA FT4

• Insulation

Ethylene Propylene Rubber protects the user from electric shocks because it is non-conducting. This layer is thermoplastic and do not succumb to deformations easily. It also creates a permanent barrier between the neutral path and the live conductors, improving its electrical conductivity.

• Jacketing and Shielding

Type EX Thermocouple Wire is shielded with aluminum foil to eliminate conductors from overlapping. Shielding also maintains the circular phase identification of the cable. CPE jacketing offers both chemical and mechanical protection.

Applications

Thermocouple EX Cable is installed through conduit systems, cable trays, overhead transmission and ducts. It is used in high heat facilities like geothermal, motor engines and heating machines.

Write Your Own Review

You're reviewing: INDUSTRIAL SINGLE PAIR TYPE EX OVERALL SHIELDED THERMOCOUPLE EXTENSION CABLE

How do you rate this product? *

 
1 1 star
2 2 star
3 3 star
4 4 star
5 5 star
Price
Value
Quality