Shipboard Cable LS3SU Multi Triad Xlpe Stranded Uncoated Copper

Shipboard Cable LS3SU Multi Triad Xlpe Stranded Uncoated Copper
Specification

1. Conductor: Stranded bare copper

2. Insulation: Cross-linked polyethylene

3. Triad: Three conductors (one of each color) cabled to form triad (optional binder tape)

4. Shield: Braided bare copper shield

5. Shield Insulation: Two sealed polyester tapes

6. Identification: Standard identification code by Method 2

7. Assembly: The required number of shielded triads cabled consecutively, fillers, binder tape

8. Overall Jacket: Cross-linked polyolefin LSZH jacket, surface marking

LS3SA, same construction with overall braided aluminum armor.
LS3SUS, same construction as LS3SU, with double overall shield.

Approvals:

• M24643/36
• MIL-I-45208A
• MIL-STD-790

  Product Name
Length
Price (Per FT.)
 
Shipboard Cable LS3SU Multi Triad Xlpe Stranded Uncoated Copper

Shipboard Cable LS3SU-19 18 AWG 19 Triad Xlpe Stranded Uncoated Copper

Armor NO
Conductor Count 19 TRIAD (TRIPLE)
Conductor Size 18 AWG (AMERICAN WIRE GAUGE)
Conductor Stranding CLASS B
IEEE 45 NO
Insulation Material XLP-CROSS LINKED POLYETHYLENE
Jacket Material PO-POLYOLEFIN
Mil Spec MIL-C 24643/35
Screen/Shield Type BRAID
Screen/Shield YES
Shield Construction INDIVIDUAL
UL NO
Watertight NO
UNSPSC Code 26121603
Mil-Spec # M24643/35-05-UN
FT.
Call 516-472-0650 for pricing
Shipboard Cable LS3SU Multi Triad Xlpe Stranded Uncoated Copper

Shipboard Cable LS3SU-14 18 AWG 14 Triad Xlpe Stranded Uncoated Copper

Armor NO
Conductor Count 14 TRIAD (TRIPLE)
Conductor Size 18 AWG (AMERICAN WIRE GAUGE)
Conductor Stranding CLASS B
IEEE 45 NO
Insulation Material XLP-CROSS LINKED POLYETHYLENE
Jacket Material PO-POLYOLEFIN
Mil Spec MIL-C 24643/35
Screen/Shield Type BRAID
Screen/Shield YES
Shield Construction INDIVIDUAL
UL NO
Watertight NO
UNSPSC Code 26121603
Mil-Spec # M24643/35-04-UN
FT.
Call 516-472-0650 for pricing
Shipboard Cable LS3SU Multi Triad Xlpe Stranded Uncoated Copper

Shipboard Cable LS3SU-10 18 AWG 10 Triad Xlpe Stranded Uncoated Copper

Armor NO
Conductor Count 10 TRIAD (TRIPLE)
Conductor Size 18 AWG (AMERICAN WIRE GAUGE)
Conductor Stranding CLASS B
IEEE 45 NO
Insulation Material XLP-CROSS LINKED POLYETHYLENE
Jacket Material PO-POLYOLEFIN
Mil Spec MIL-C 24643/35
Screen/Shield Type BRAID
Screen/Shield YES
Shield Construction INDIVIDUAL
UL NO
Watertight NO
UNSPSC Code 26121603
Mil-Spec # M24643/35-03-UN
FT.
Call 516-472-0650 for pricing
Shipboard Cable LS3SU Multi Triad Xlpe Stranded Uncoated Copper

Shipboard Cable LS3SU-7 18 AWG 7 Triad Xlpe Stranded Uncoated Copper

Armor NO
Conductor Count 7 TRIAD (TRIPLE)
Conductor Size 18 AWG (AMERICAN WIRE GAUGE)
Conductor Stranding CLASS B
IEEE 45 NO
Insulation Material XLP-CROSS LINKED POLYETHYLENE
Jacket Material PO-POLYOLEFIN
Mil Spec MIL-C 24643/35
Screen/Shield Type BRAID
Screen/Shield YES
Shield Construction INDIVIDUAL
UL NO
Watertight NO
UNSPSC Code 26121603
Mil-Spec # M24643/35-02-UN
FT.
Call 516-472-0650 for pricing
Shipboard Cable LS3SU Multi Triad Xlpe Stranded Uncoated Copper

Shipboard Cable LS3SU-3 18 AWG 3 Triad Xlpe Stranded Uncoated Copper

Armor NO
Conductor Count 3 TRIAD (TRIPLE)
Conductor Size 18 AWG (AMERICAN WIRE GAUGE)
Conductor Stranding CLASS B
IEEE 45 NO
Insulation Material XLP-CROSS LINKED POLYETHYLENE
Jacket Material PO-POLYOLEFIN
Mil Spec MIL-C 24643/35
Screen/Shield Type BRAID
Screen/Shield YES
Shield Construction INDIVIDUAL
UL NO
Watertight NO
UNSPSC Code 26121603
Mil-Spec # M24643/35-01-UN
FT.
Call 516-472-0650 for pricing

Specification

1. Conductor: Stranded bare copper

2. Insulation: Cross-linked polyethylene

3. Triad: Three conductors (one of each color) cabled to form triad (optional binder tape)

4. Shield: Braided bare copper shield

5. Shield Insulation: Two sealed polyester tapes

6. Identification: Standard identification code by Method 2

7. Assembly: The required number of shielded triads cabled consecutively, fillers, binder tape

8. Overall Jacket: Cross-linked polyolefin LSZH jacket, surface marking

LS3SA, same construction with overall braided aluminum armor.
LS3SUS, same construction as LS3SU, with double overall shield.

Approvals:

• M24643/36
• MIL-I-45208A
• MIL-STD-790

Details

Applications:

Type LS3SU/A/S cables individually shielded multiconductor constructions suitable for non-watertight, non-flexing service. They are available both with and without armor and a double overall shield. They may be used to provide shielded circuits for combat systems, interior communications, lighting and power, where shielding of 400 Hz is required. The overall shielding conforms to the surface transfer impedance and EMP response time requirements of the specification.

Write Your Own Review

You're reviewing: Shipboard Cable LS3SU Multi Triad Xlpe Stranded Uncoated Copper

How do you rate this product? *

 
1 1 star
2 2 star
3 3 star
4 4 star
5 5 star
Quality
Price
Value