Shipboard Cable MNSI Multi Conductor Overall Shield BC PVC Nylon

Shipboard Cable MNSI Multi Conductor Overall Shield BC PVC Nylon
Specification

• Conuctors: Class B stranded bare copper per UL 83 and 62

• Insulation: Polyvinyl Chloride (PVC) per UL 62 for Type TFFN (16 AWG) or UL 83 for Type THWN or THHN wire, nominal thickness is 15 mils

• Insulation Jacket: Each insulated conductor is jacketed with nylon meeting UL 62 for Type TFFN or UL 83 for Type THWN or THHN wire, minimum thickness is 4 mils

• Color Code: ICEA Method 1, Table E-2 (formerly K-2)

• Assembly: Conductors are cabled with fillers where necessary to make round

• Shield: Aluminum/Mylar helically applied with tinned copper drain wire

• Overall Jacket: Sunlight-resistant Polyvinyl Chloride (PVC) per UL 1277

• Standards: Meets UL 1277 requirements for Type TC cables having THWN or THHN (TFFN) conductors, cables are listed for direct burial and meet the IEEE 1202, IEE 383 and UL 1685. 70,000 BTU/HR flame tests

• Ampacity: Based on not more than three conductors in raceway or cable or earth with an ambient temperature of 30°C per NEC Table 310.16, the values have been derated where applicable

• Temperature: 90ºC

• Voltage: 600 V

  Product Name
Length
Price (Per FT.)
 
Shipboard Cable MNSI Multi Conductor Overall Shield BC PVC Nylon

Shipboard Cable MNSI-24-3 16 AWG 24 Conductor Overall Shield BC PVC Nylon

FT.
Call 516-472-0650 for pricing
Shipboard Cable MNSI Multi Conductor Overall Shield BC PVC Nylon

Shipboard Cable MNSI-20-3 16 AWG 20 Conductor Overall Shield BC PVC Nylon

FT.
Call 516-472-0650 for pricing
Shipboard Cable MNSI Multi Conductor Overall Shield BC PVC Nylon

Shipboard Cable MNSI-14-3 16 AWG 14 Conductor Overall Shield BC PVC Nylon

FT.
Call 516-472-0650 for pricing
Shipboard Cable MNSI Multi Conductor Overall Shield BC PVC Nylon

Shipboard Cable MNSI-10-3 16 AWG 10 Conductor Overall Shield BC PVC Nylon

FT.
Call 516-472-0650 for pricing
Shipboard Cable MNSI Multi Conductor Overall Shield BC PVC Nylon

Shipboard Cable MNSI-7-3 16 AWG 7 Conductor Overall Shield BC PVC Nylon

FT.
Call 516-472-0650 for pricing
Shipboard Cable MNSI Multi Conductor Overall Shield BC PVC Nylon

Shipboard Cable MNSI-30-4 14 AWG 30 Conductor Overall Shield BC PVC Nylon

FT.
Call 516-472-0650 for pricing
Shipboard Cable MNSI Multi Conductor Overall Shield BC PVC Nylon

Shipboard Cable MNSI-24-4 14 AWG 24 Conductor Overall Shield BC PVC Nylon

FT.
Call 516-472-0650 for pricing
Shipboard Cable MNSI Multi Conductor Overall Shield BC PVC Nylon

Shipboard Cable MNSI-16-4 14 AWG 16 Conductor Overall Shield BC PVC Nylon

FT.
Call 516-472-0650 for pricing
Shipboard Cable MNSI Multi Conductor Overall Shield BC PVC Nylon

Shipboard Cable MNSI-10-4 14 AWG 10 Conductor Overall Shield BC PVC Nylon

FT.
Call 516-472-0650 for pricing
Shipboard Cable MNSI Multi Conductor Overall Shield BC PVC Nylon

Shipboard Cable MNSI-7-4 14 AWG 7 Conductor Overall Shield BC PVC Nylon

FT.
Call 516-472-0650 for pricing
Shipboard Cable MNSI Multi Conductor Overall Shield BC PVC Nylon

Shipboard Cable MNSI-20-6 12 AWG 20 Conductor Overall Shield BC PVC Nylon

FT.
Call 516-472-0650 for pricing
Shipboard Cable MNSI Multi Conductor Overall Shield BC PVC Nylon

Shipboard Cable MNSI-6-6 12 AWG 6 Conductor Overall Shield BC PVC Nylon

FT.
Call 516-472-0650 for pricing

Specification

• Conuctors: Class B stranded bare copper per UL 83 and 62

• Insulation: Polyvinyl Chloride (PVC) per UL 62 for Type TFFN (16 AWG) or UL 83 for Type THWN or THHN wire, nominal thickness is 15 mils

• Insulation Jacket: Each insulated conductor is jacketed with nylon meeting UL 62 for Type TFFN or UL 83 for Type THWN or THHN wire, minimum thickness is 4 mils

• Color Code: ICEA Method 1, Table E-2 (formerly K-2)

• Assembly: Conductors are cabled with fillers where necessary to make round

• Shield: Aluminum/Mylar helically applied with tinned copper drain wire

• Overall Jacket: Sunlight-resistant Polyvinyl Chloride (PVC) per UL 1277

• Standards: Meets UL 1277 requirements for Type TC cables having THWN or THHN (TFFN) conductors, cables are listed for direct burial and meet the IEEE 1202, IEE 383 and UL 1685. 70,000 BTU/HR flame tests

• Ampacity: Based on not more than three conductors in raceway or cable or earth with an ambient temperature of 30°C per NEC Table 310.16, the values have been derated where applicable

• Temperature: 90ºC

• Voltage: 600 V

Details

Description:

PVC-nylon insulation
Shielded
PVC jacket
90°C, 600 V

Applications:

• Designed for power and control, telemetering, relay control, traffic control, switching, lighting and signal transmission
• May be used in Class I, Div. 2 and Class II, Div. 2 Hazardous Locations per NEC Art. 501 and 502
•  These cables also conform to Art. 392 "Cable Trays" and Art. 336 "Power and Control Tray Cable