MV105 OR MV90 NON SHIELDED XLP 133% INSULATION COPPER CABLE 5KV

MV105 OR MV90 NON SHIELDED XLP 133% INSULATION COPPER CABLE 5KV
Specification
Applications:

Uses for such as power circuits up to 5000 Volts when fixed in open air, conduit or duct.  In applications such as chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations and generating stations. National Electric Code accepted for uses within 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions.

Conductor:

Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact), with a semi-conducting conductor shield.

Insulation:

Cross-linked polyethylene (XLP) per ICEA regulations.

Additional Standards: 
  • ICEA S-96-659
  • UL Standard 1072
  • NEMA WC 71
  Product Name
Length
Price (Per FT.)
 
MV105 OR MV90 NON SHIELDED XLP 133% INSULATION COPPER CABLE 2.4KV-5KV

8 MV105 OR MV90 NON SHIELDED XLP 133% INSULATION COPPER CABLE 5KV

FT.
Call 516-472-0650 for pricing
MV105 OR MV90 NON SHIELDED XLP 133% INSULATION COPPER CABLE 2.4KV-5KV

6 MV105 OR MV90 NON SHIELDED XLP 133% INSULATION COPPER CABLE 5KV

FT.
Call 516-472-0650 for pricing
MV105 OR MV90 NON SHIELDED XLP 133% INSULATION COPPER CABLE 2.4KV-5KV

4 MV105 OR MV90 NON SHIELDED XLP 133% INSULATION COPPER CABLE 5KV

FT.
Call 516-472-0650 for pricing
MV105 OR MV90 NON SHIELDED XLP 133% INSULATION COPPER CABLE 2.4KV-5KV

2 MV105 OR MV90 NON SHIELDED XLP 133% INSULATION COPPER CABLE 5KV

FT.
Call 516-472-0650 for pricing
MV105 OR MV90 NON SHIELDED XLP 133% INSULATION COPPER CABLE 2.4KV-5KV

1 MV105 OR MV90 NON SHIELDED XLP 133% INSULATION COPPER CABLE 5KV

FT.
Call 516-472-0650 for pricing
MV105 OR MV90 NON SHIELDED XLP 133% INSULATION COPPER CABLE 2.4KV-5KV

1/0 MV105 OR MV90 NON SHIELDED XLP 133% INSULATION COPPER CABLE 5KV

FT.
Call 516-472-0650 for pricing
MV105 OR MV90 NON SHIELDED XLP 133% INSULATION COPPER CABLE 2.4KV-5KV

2/0 MV105 OR MV90 NON SHIELDED XLP 133% INSULATION COPPER CABLE 5KV

FT.
Call 516-472-0650 for pricing
MV105 OR MV90 NON SHIELDED XLP 133% INSULATION COPPER CABLE 2.4KV-5KV

3/0 MV105 OR MV90 NON SHIELDED XLP 133% INSULATION COPPER CABLE 5KV

FT.
Call 516-472-0650 for pricing
MV105 OR MV90 NON SHIELDED XLP 133% INSULATION COPPER CABLE 2.4KV-5KV

4/0 MV105 OR MV90 NON SHIELDED XLP 133% INSULATION COPPER CABLE 5KV

FT.
Call 516-472-0650 for pricing
MV105 OR MV90 NON SHIELDED XLP 133% INSULATION COPPER CABLE 2.4KV-5KV

250 MV105 OR MV90 NON SHIELDED XLP 133% INSULATION COPPER CABLE 5KV

FT.
Call 516-472-0650 for pricing
MV105 OR MV90 NON SHIELDED XLP 133% INSULATION COPPER CABLE 2.4KV-5KV

500 MV105 OR MV90 NON SHIELDED XLP 133% INSULATION COPPER CABLE 5KV

FT.
Call 516-472-0650 for pricing
MV105 OR MV90 NON SHIELDED XLP 133% INSULATION COPPER CABLE 2.4KV-5KV

1000 MV105 OR MV90 NON SHIELDED XLP 133% INSULATION COPPER CABLE 5KV

FT.
Call 516-472-0650 for pricing

Specification

Applications:

Uses for such as power circuits up to 5000 Volts when fixed in open air, conduit or duct.  In applications such as chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations and generating stations. National Electric Code accepted for uses within 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions.

Conductor:

Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact), with a semi-conducting conductor shield.

Insulation:

Cross-linked polyethylene (XLP) per ICEA regulations.

Additional Standards: 
  • ICEA S-96-659
  • UL Standard 1072
  • NEMA WC 71

Details

MV105 OR MV90 Non Shielded XLP 133% Insulation Copper Power Cable 5Kv

Beyond any reasonable doubt, the cable is proven to be sturdy and reliable. It has greater convenience and high performance, due to its ease of installation. A cable which is qualified for use in very strenuous and demanding conditions and still guarantees you an everlasting service in your system. This is a cable worth considering.

Let us talk about the spectacular features of this cable.

  • Conductor

Both MV105 and MV90 cables are made from copper conductors. The copper conductor used is soft and annealed. Besides it is bare, that is why the cable is called unshielded. Class B of the conductor used is stranded and compressed according to the provisions of ASTM B-8 or compacted as per the ASTM B-496. This conductor has also a semi-conductor shield which helps to reinforce its efficiency and strength.

  • Insulation

To make the right choice of a cable during your purchase then you should as well check keenly the insulation features of that particular cable. A cable without good and sturdy insulation is destined to ruin your electrical connection. This brand of Nassau National Cable products has a cross-linked polyethylene insulation system. This insulation is designed according to the ICEA regulations.

Applications

Knowing where and how to use this cable is extremely vital. Now as I mentioned earlier, load size resonates directly to the type and size of cable to use. This cable is used in power circuits where the voltage rates up to 5 Kilo volts. It is appropriate for installation in open air, conduit and duct installations.

This power cable has been applied in various systems in chemical plants, various industrial plants, steel mills, refineries, commercial buildings, utility substations and in generator stations. This cable has been tested and proved to work efficiently.

 Operation

The National Electric Code, which is a very renowned and accepted standardization body, has approved this cable to be used within 90 degrees Celsius. It can however be used in 130 degrees Celsius emergency overloaded conditions. During a short circuit conditions, the cable can tolerate a temperature of 250 degrees Celsius.

Question and Answer:

Frequently Asked Questions - MV105 OR MV90 NON SHIELDED EPR HYPALON HEAVY WALL 133% COPPER CABLE 2.4kV-5kV and MV105 OR MV90 NON SHIELDED XLP 133% INSULATION COPPER CABLE 5KV

What are the specific applications of MV105 or MV90 Non Shielded EPR Hypalon Heavy Wall 133% Copper 2.4kV-5kV Cables and MV105 or MV90 Non Shielded XLP 133% Insulation Copper cables 5kV?

MV105 or MV90 Non Shielded EPR Hypalon Heavy Wall 133% Copper cable 2.4kV-5kV Cables are suitable for corrosive environments in power circuits up to 2000V which are installed in open air, conduit & duct; cable tray when CT rated, in wet and dry conditions. These power cables are appropriate for chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations and general stations.

MV105 or MV90 Non Shielded XLP 133% Insulation Copper cables 5kV also are used in similar situations, just that it can be used in power circuits up to 5000V.

 

What type of conductor is used for MV105 or MV90 Non Shielded EPR Hypalon Heavy Wall 133% Copper 2.4kV-5kV Cables and MV105 or MV90 Non Shielded XLP 133% Insulation Copper cables 5kV?

The power cables have a semi-conducting conductor shield of soft bare annealed copper which qualify the ASTM B-3. It also has Class B stranding as per ASTM B-8 (compressed) or ASTM B-496 (compact).

 

What is the insulation used for MV105 or MV90 Non Shielded EPR Hypalon Heavy Wall 133% Copper 2.4kV-5kV Cables and MV105 or MV90 Non Shielded XLP 133% Insulation Copper cables 5kV?

For insulation, MV105 or MV90 Non Shielded EPR Hypalon Heavy Wall 133% Copper cable 2.4kV-5kV Cablesuse Ethylene propylene rubber (EPR) per ICEA standards. 

MV105 or MV90 Non Shielded XLP 133% Insulation Copper cables 5kV uses Cross-linked polyethylene (XLP) per ICEA regulations.

 

What are the regulations and uses of MV105 or MV90 Non Shielded EPR Hypalon Heavy Wall 133% Copper 2.4kV-5kV Cables and MV105 or MV90 Non Shielded XLP 133% Insulation Copper cables 5kVunder specific temperature conditions?

The National Electric Code has allowed the use of both thepowercables at 90°C for continuous operation, 130°C for emergency overload conditions and 250°C for short circuit conditions.

 

What is the difference between MV105 or MV90 Non Shielded EPR Hypalon Heavy Wall 133% Copper 2.4kV-5kV Cables and MV105 or MV90 Non Shielded XLP 133% Insulation Copper cables 5kV?

The main difference between bothcables lies in the fact that MV105 or MV90 Non Shielded EPR Hypalon Heavy Wall 133% Copper cable 2.4kV-5kV Cables have Jacket made of Chloro-sulfonated polyethylene (CSPE/Hypalon®) as per ICEA standards. It also complies with flame tests - UL and IEEE 383 70,000 BTU/hr flame test – for CT-listed sizes 1/0 AWG and larger.

 

What are the national and international standards to which MV105 or MV90 Non Shielded EPR Hypalon Heavy Wall 133% Copper 2.4kV-5kV Cables and MV105 or MV90 Non Shielded XLP 133% Insulation Copper cables 5kVconform?

Both Power Cables conform to all major national and international technical standards of the industry such as:

  • ICEA S-96-659
  • UL Standard 1072
  • NEMA WC71

Video

Write Your Own Review

You're reviewing: MV105 OR MV90 NON SHIELDED XLP 133% INSULATION COPPER CABLE 5KV

How do you rate this product? *

 
1 1 star
2 2 star
3 3 star
4 4 star
5 5 star
Quality
Price
Value