MV105 THREE CONDUCTOR SHIELDED EPR INSULATION PVC JACKET 5KV 133% 8KV 100% INSULATION

MV105 THREE CONDUCTOR SHIELDED EPR INSULATION PVC JACKET 5KV 133% 8KV 100% INSULATION
Specification

Power Cable

5kV / 8kV UL Type MV-105, 105°C

Three Conductor, Shielded

EPR Insulation, PVC Jacket

5kV 133% Insulation Level

8kV 100% Insulation Level

Copper Conductor

Application:

Appropriate for all situations of corrosive environments in power circuits up to 5,000V & 8,000V in all installations of open air, conduit, and duct, cable tray when CT rated, in wet and dry locations. Main uses are for chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations and generating stations. National Electric Code permitted for use at 105°C for continuous operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions.

Conductor:

Has a semi-conducting conductor shield, with soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact). The ground conductor has a soft bare annealedcompressedcopperper ASTM B-3, and withstranding ofClass B per ASTM B-8 sized in accordance to UL Standard 1072.

Insulation:

Ethylene propylene rubber (EPR) per ICEA S-97-682 with a semi-conducting insulation shield.

Shield:

Uncoated copper tape with a minimum 12.5% overlap per ICEA S-97-682.

Jacket:

Sunlight-resistant PVC per ICEA S-97-682 and UL Standard 1072.

Standards:

  • ICEA S-93-639

  • NEMA WC74

  • AEIC CS8

  • Federal Specification J-C-30B

  Product Name
Length
Price (Per FT.)
 
MV105 THREE CONDUCTOR SHIELDED EPR INSULATION PVC JACKET 5KV 133% 8KV 100% INSULATION

6 MV105 THREE CONDUCTOR SHIELDED EPR INSULATION PVC JACKET 5KV 133% 8KV 100% INSULATION

FT.
Call 516-472-0650 for pricing
MV105 THREE CONDUCTOR SHIELDED EPR INSULATION PVC JACKET 5KV 133% 8KV 100% INSULATION

4 MV105 THREE CONDUCTOR SHIELDED EPR INSULATION PVC JACKET 5KV 133% 8KV 100% INSULATION

FT.
$2.44

MV105 THREE CONDUCTOR SHIELDED EPR INSULATION PVC JACKET 5KV 133% 8KV 100% INSULATION

2 MV105 THREE CONDUCTOR SHIELDED EPR INSULATION PVC JACKET 5KV 133% 8KV 100% INSULATION

FT.
$3.97

MV105 THREE CONDUCTOR SHIELDED EPR INSULATION PVC JACKET 5KV 133% 8KV 100% INSULATION

1 MV105 THREE CONDUCTOR SHIELDED EPR INSULATION PVC JACKET 5KV 133% 8KV 100% INSULATION

FT.
Call 516-472-0650 for pricing
MV105 THREE CONDUCTOR SHIELDED EPR INSULATION PVC JACKET 5KV 133% 8KV 100% INSULATION

1/0 MV105 THREE CONDUCTOR SHIELDED EPR INSULATION PVC JACKET 5KV 133% 8KV 100% INSULATION

FT.
$4.60

MV105 THREE CONDUCTOR SHIELDED EPR INSULATION PVC JACKET 5KV 133% 8KV 100% INSULATION

2/0 MV105 THREE CONDUCTOR SHIELDED EPR INSULATION PVC JACKET 5KV 133% 8KV 100% INSULATION

FT.
$5.40

MV105 THREE CONDUCTOR SHIELDED EPR INSULATION PVC JACKET 5KV 133% 8KV 100% INSULATION

3/0 MV105 THREE CONDUCTOR SHIELDED EPR INSULATION PVC JACKET 5KV 133% 8KV 100% INSULATION

FT.
Call 516-472-0650 for pricing
MV105 THREE CONDUCTOR SHIELDED EPR INSULATION PVC JACKET 5KV 133% 8KV 100% INSULATION

4/0 MV105 THREE CONDUCTOR SHIELDED EPR INSULATION PVC JACKET 5KV 133% 8KV 100% INSULATION

FT.
$6.00

MV105 THREE CONDUCTOR SHIELDED EPR INSULATION PVC JACKET 5KV 133% 8KV 100% INSULATION

250 MV105 THREE CONDUCTOR SHIELDED EPR INSULATION PVC JACKET 5KV 133% 8KV 100% INSULATION

FT.
$8.80

MV105 THREE CONDUCTOR SHIELDED EPR INSULATION PVC JACKET 5KV 133% 8KV 100% INSULATION

350 MV105 THREE CONDUCTOR SHIELDED EPR INSULATION PVC JACKET 5KV 133% 8KV 100% INSULATION

FT.
$9.50

MV105 THREE CONDUCTOR SHIELDED EPR INSULATION PVC JACKET 5KV 133% 8KV 100% INSULATION

500 MV105 THREE CONDUCTOR SHIELDED EPR INSULATION PVC JACKET 5KV 133% 8KV 100% INSULATION

FT.
Call 516-472-0650 for pricing
MV105 THREE CONDUCTOR SHIELDED EPR INSULATION PVC JACKET 5KV 133% 8KV 100% INSULATION

750 MV105 THREE CONDUCTOR SHIELDED EPR INSULATION PVC JACKET 5KV 133% 8KV 100% INSULATION

FT.
Call 516-472-0650 for pricing

Specification

Power Cable

5kV / 8kV UL Type MV-105, 105°C

Three Conductor, Shielded

EPR Insulation, PVC Jacket

5kV 133% Insulation Level

8kV 100% Insulation Level

Copper Conductor

Application:

Appropriate for all situations of corrosive environments in power circuits up to 5,000V & 8,000V in all installations of open air, conduit, and duct, cable tray when CT rated, in wet and dry locations. Main uses are for chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations and generating stations. National Electric Code permitted for use at 105°C for continuous operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions.

Conductor:

Has a semi-conducting conductor shield, with soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact). The ground conductor has a soft bare annealedcompressedcopperper ASTM B-3, and withstranding ofClass B per ASTM B-8 sized in accordance to UL Standard 1072.

Insulation:

Ethylene propylene rubber (EPR) per ICEA S-97-682 with a semi-conducting insulation shield.

Shield:

Uncoated copper tape with a minimum 12.5% overlap per ICEA S-97-682.

Jacket:

Sunlight-resistant PVC per ICEA S-97-682 and UL Standard 1072.

Standards:

  • ICEA S-93-639

  • NEMA WC74

  • AEIC CS8

  • Federal Specification J-C-30B

Details

MV105 THREE CONDUCTOR 5KV POWER CABLE

This cable is meant for heavy duty applications in corrosive environments given that it has three conductors. It has a voltage rating of 5000 volts and 8000 volts. The operating temperature of this cable is slightly higher compared to the previous cables. It normally operates at 105 degrees Celsius but in case of an emergency overload it can withstand temperatures up to 140 degrees Celsius and if a short circuit occurs it can withstand a temperature of 250 degrees Celsius. It’s mainly used in chemical plants, industrial plants, refineries and commercial buildings.

This cable has three copper conductors and a semi-conducting shield on the conductors. Among the three conductors is a ground conductor which also withholds current under normal operation of the cable. The conductors on this cable are also stranded which enhances flexibility of the conductors. The insulation is constructed from Ethylene propylene rubber (EPR) which also has a semi-conducting shield added to it. The insulation for the 5000 volt wire has 100 % coverage while for the 8000 volt option the coverage is 133%.

An overall shield is added to prevent mechanical and electromagnetic interferences from affecting the inner parts of the cable. The overall shield is made from uncoated copper tape. The cable has an outer jacket which conceals the inner components of the cable and is made from PVC material.

Industrial ratings and approvals

 It’s always advisable to buy products that have been tested and proven safe for use. Products are usually tested to ensure that they are in good condition and safe to use by the public and it also proves that the product is genuine. Many suppliers out their sell products that have not been tested by international agencies but since we at Nassau national cable care about you and your safety we ensure our products are tested. Our products are tested by the following agencies;

  • National Electric Code (NEC)
  • Federal Specification J-C-30B
  • ICEA S-93-639
  • NEMA WC74
  • AEIC CS8

With the above standards you can trust that our products are genuine

Why go for the medium voltage power cable?

This cable has numerous benefits that come with it to the consumer. First and foremost this cable can be used in a wide range of applications to supply power including corrosive environments. It also has outstanding features that make it effective in performing its functions which includes durability and flexibility. This cable can also be recycled hence it can be utilized elsewhere in case it wears out which can take a lifetime.

This cable can be found in many electrical outlets worldwide but before you settle on a supplier it’s advisable to ensure the products are genuine. For more information on this cable and other wire products get in touch with us via our live chat on our website and we will gladly respond to your queries. I hope you found this review helpful.

Question and Answer:

Frequently Asked Questions - MV105 THREE CONDUCTOR SHIELDED EPR INSULATION PVC JACKET 5KV 133% 8KV 100% INSULATION and MV105 THREE CONDUCTOR NON-SHIELDED EPR INSULATION PVC JACKET COPPER POWER CABLE 2.4kV

What are the specific applications of MV105 Three Conductor Non-Shielded EPR Insulation PVC Jacket Copper2.4kV Power Cables and MV105 Three Conductor Shielded EPR Insulation PVC Jacket 5kV 133%8kV 100% Power Cables?

MV105 Three Conductor Non-Shielded EPR Insulation PVC Jacket Copper 2.4kV Power Cables are suitable for corrosive environments in power circuits up to 2400V which are installed in open air, conduit & duct; cable tray when CT rated, in wet and dry conditions. These power cables are appropriate for chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations and general stations.

MV105 Three Conductor Shielded EPR Insulation PVC Jacket 5kV 133% 8kV 100% Power Cables also are used in similar situations, just that it can be used in power circuits up to 5,000V & 8,000V.

What is the difference between MV105 Three Conductor Non-Shielded EPR Insulation PVC Jacket Copper2.4kV Power Cables and MV105 Three Conductor Shielded EPR Insulation PVC Jacket 5kV 133%8kV 100% Power Cables?

The main difference between bothcables lies in the fact that MV105 Three Conductor Shielded EPR Insulation PVC Jacket 5kV 133% 8kV 100% Power Cables have a ground conductor with soft bare annealed compressed copper per ASTM B-3, and with stranding of Class B per ASTM B-8 sized in accordance to UL Standard 1072.

What is the insulation used for MV105 Three Conductor Non-Shielded EPR Insulation PVC Jacket Copper2.4kV Power Cables and MV105 Three Conductor Shielded EPR Insulation PVC Jacket 5kV 133%8kV 100% Power Cables?

Both the power cables have Ethylene propylene rubber (EPR) per ICEA S-97-682 with a semi-conducting insulation shield.

What are the regulations and uses of MV105 Three Conductor Non-Shielded EPR Insulation PVC Jacket Copper2.4kV Power Cables and MV105 Three Conductor Shielded EPR Insulation PVC Jacket 5kV 133%8kV 100% Power Cables under specific temperature conditions?

The National Electric Code has allowed the use of both thepowercables at 105°C for continuous operation, 140°C for emergency overload conditions and 250°C for short circuit conditions.

What are the national and international standards to which MV105 Three Conductor Non-Shielded EPR Insulation PVC Jacket Copper2,4kV Power Cables and MV105 Three Conductor Shielded EPR Insulation PVC Jacket 5kV 133%8kV 100% Power Cables conform?

Both MV105 Three Conductor Non-Shielded EPR Insulation PVC Jacket Copper 2,4kV Power Cables and MV105 Three Conductor Shielded EPR Insulation PVC Jacket 5kV 133% 8kV 100% Power Cables conforms to all major national and international technical standards of the industry such as:

  • ICEA S-93-639
  • NEMA WC74
  • AEIC CS8
  • Federal Specification J-C-30B