TYPE UL MV105 SHIELDED EPR INSULATION CPE JACKET 100% INSULATION COPPER POWER CABLE 15Kv

TYPE UL MV105 SHIELDED EPR INSULATION CPE JACKET 100% INSULATION COPPER POWER CABLE 15Kv
Specification

Power Cable

15KV UL Type MV-105, 150°C

Single Conductor, Shielded

EPR Insulation, CPE Jacket

100% Insulation Level,Copper Conductor

Application:

Appropriate for all situations of corrosive environments in power circuits up to 15,000V in all installations of open air, conduit, and duct, cable tray when CT rated, in wet and dry locations. Main uses are for chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations and generating stations. National Electric Code permitted for use at 105°C for continuous operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions.

Conductor:

Has a semi-conducting conductor shield, with soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).

Insulation:

Ethylene propylene rubber (EPR) per ICEA S-97-682 with a semi-conducting insulation shield.

Shield:

Shielded wires of six ridged copper which are embedded longitudinally in an exterior semi-conducting CPE jacket per ICEA S-97-682.

Jacket:

Sunlight-resistant CPE per ICEA S-97-682 and UL Standard 1072.

Standards:

  • ICEA S-93-639

  • NEMA WC74

  • AEIC CS8

Specification

Power Cable

15KV UL Type MV-105, 150°C

Single Conductor, Shielded

EPR Insulation, CPE Jacket

100% Insulation Level,Copper Conductor

Application:

Appropriate for all situations of corrosive environments in power circuits up to 15,000V in all installations of open air, conduit, and duct, cable tray when CT rated, in wet and dry locations. Main uses are for chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations and generating stations. National Electric Code permitted for use at 105°C for continuous operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions.

Conductor:

Has a semi-conducting conductor shield, with soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).

Insulation:

Ethylene propylene rubber (EPR) per ICEA S-97-682 with a semi-conducting insulation shield.

Shield:

Shielded wires of six ridged copper which are embedded longitudinally in an exterior semi-conducting CPE jacket per ICEA S-97-682.

Jacket:

Sunlight-resistant CPE per ICEA S-97-682 and UL Standard 1072.

Standards:

  • ICEA S-93-639

  • NEMA WC74

  • AEIC CS8

Details

Frequently Asked Questions - TYPE UL MV105 EPR INSULATION CPE JACKET SHIELDED 100% INSULATION COPPER POWER CABLE 15kVand TYPE UL MV105 SHIELDED EPR INSULATION PVC JACKET 133% INSULATION COPPER POWER CABLE 15kV

What are the specific applications of Type UL MV105 EPR Insulation CPE Jacket Shielded 100% Insulation Copper Power Cable 15kV and Type UL MV105 Shielded EPR Insulation PVC Jacket 133%Insulation Copper Power Cable 15kV?

These power cablesare suitable for corrosive environments in power circuits up to 15,000V which are installed in open air, conduit & duct; cable tray when CT rated, in wet and dry conditions. These power cables are appropriate for chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations and general stations.

What is the type of conductor used for Type UL MV105 EPR Insulation CPE Jacket Shielded 100% Insulation Copper Power Cable 15kV and Type UL MV105 Shielded EPR Insulation PVC Jacket 133%Insulation Copper Power Cable 15kV?

The power cables have a semi-conducting conductor shield, with a compacted soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496.

What is the insulation used for Type UL MV105 EPR Insulation CPE Jacket Shielded 100% Insulation Copper Power Cable 15kV and Type UL MV105 Shielded EPR Insulation PVC Jacket 133%Insulation Copper Power Cable 15kV?

Both the power cablesType UL MV105 EPR Insulation CPE Jacket Shielded 100% Insulation Copper Power Cable 15kV and Type UL MV105 Shielded EPR Insulation PVC Jacket 133% Insulation Copper Power Cable 15kV have Ethylene propylene rubber (EPR) per ICEA S-97-682 with a semi-conducting insulation shield.

What are the regulations and uses of Type UL MV105 EPR Insulation CPE Jacket Shielded 100% Insulation Copper Power Cable 15kV and Type UL MV105 Shielded EPR Insulation PVC Jacket 133%Insulation Copper Power Cable 15kVunder specific temperature conditions?

The National Electric Code has allowed the use of Type UL MV105 EPR Insulation CPE Jacket Shielded 100% Insulation Copper Power Cable 15kV at 90°C for continuous operation, 130°C for emergency overload conditions and 250°C for short circuit conditions.

For Type UL MV105 Shielded EPR Insulation PVC Jacket 133% Insulation Copper Power Cable 15kV, its 105°C for continuous operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions.

What are the national and international standards to which Type UL MV105 EPR Insulation CPE Jacket Shielded 100% Insulation Copper Power Cable 15kV and Type UL MV 105 Shielded EPR Insulation PVC Jacket 133%Insulation Copper Power Cable 15kVconform?

Both the Power Cables conforms to all major national and international technical standards of the industry such as:

  • ICEA S-93-639
  • ICEA S-97-682
  • NEMA WC74
  • AEIC CS8
  • Federal Specification J-C-30B
  • UL Standard 1072

Video

Write Your Own Review

You're reviewing: TYPE UL MV105 SHIELDED EPR INSULATION CPE JACKET 100% INSULATION COPPER POWER CABLE 15Kv

How do you rate this product? *

 
1 1 star
2 2 star
3 3 star
4 4 star
5 5 star
Quality
Price
Value