TYPE UL MV105 SHIELDED EPR INSULATION PVC JACKET 133% INSULATION COPPER POWER CABLE 15Kv

TYPE UL MV105 SHIELDED EPR INSULATION PVC JACKET 133% INSULATION COPPER POWER CABLE 15Kv
Specification
Power Cable
15KV UL Type MV-105, 150°C
Single Conductor, Shielded
EPR Insulation, PVC Jacket
133% Insulation Level, Copper Conductor
Application:

Appropriate for all situations of corrosive environments in power circuits up to 15,000V in all installations of open air, conduit, and duct, cable tray when CT rated, in wet and dry locations. Main uses are for chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations and generating stations. National Electric Code permitted for use at 105°C for continuous operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions.

Conductor:

Has a semi-conducting conductor shield, with soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).

Insulation:

Ethylene propylene rubber (EPR) per ICEA S-97-682 with a semi-conducting insulation shield.

Shield:

Uncoated copper tape with a minimum 12.5% overlap per ICEA S-97-682.

Jacket:

Sunlight-resistant PVC per ICEA S-97-682 and UL Standard 1072.

Standards:

  • ICEA S-93-639
  • NEMA WC74
  • AEIC CS8
  • Federal Specification J-C-30B 

Specification

Power Cable
15KV UL Type MV-105, 150°C
Single Conductor, Shielded
EPR Insulation, PVC Jacket
133% Insulation Level, Copper Conductor
Application:

Appropriate for all situations of corrosive environments in power circuits up to 15,000V in all installations of open air, conduit, and duct, cable tray when CT rated, in wet and dry locations. Main uses are for chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations and generating stations. National Electric Code permitted for use at 105°C for continuous operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions.

Conductor:

Has a semi-conducting conductor shield, with soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).

Insulation:

Ethylene propylene rubber (EPR) per ICEA S-97-682 with a semi-conducting insulation shield.

Shield:

Uncoated copper tape with a minimum 12.5% overlap per ICEA S-97-682.

Jacket:

Sunlight-resistant PVC per ICEA S-97-682 and UL Standard 1072.

Standards:

  • ICEA S-93-639
  • NEMA WC74
  • AEIC CS8
  • Federal Specification J-C-30B 

Details

Power Cable
15KV UL Type MV-105, 150°C
Single Conductor, Shielded
EPR Insulation, PVC Jacket
133% Insulation Level, Copper Conductor
Application:

Appropriate for all situations of corrosive environments in power circuits up to 15,000V in all installations of open air, conduit, and duct, cable tray when CT rated, in wet and dry locations. Main uses are for chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations and generating stations. National Electric Code permitted for use at 105°C for continuous operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions.

Conductor:

Has a semi-conducting conductor shield, with soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).

Insulation:

Ethylene propylene rubber (EPR) per ICEA S-97-682 with a semi-conducting insulation shield.

Shield:

Uncoated copper tape with a minimum 12.5% overlap per ICEA S-97-682.

Jacket:

Sunlight-resistant PVC per ICEA S-97-682 and UL Standard 1072.

Standards:

  • ICEA S-93-639
  • NEMA WC74
  • AEIC CS8
  • Federal Specification J-C-30B 

 