C-L-X Type MV-105 or MC-HL - Yellow Jacket

C-L-X Type MV-105 or MC-HL - Yellow Jacket
Specification

Applications

C-L-X power cables are recommended as an economical alternate to a wire in conduit system. They are designed specifically for use as feeders or branch circuits in industrial and utility power distribution systems. C-L-X power cables may be installed in both exposed and concealed work, wet and dry locations, directly buried in the earth, or embedded in concrete. They may be installed on metal racks, troughs, in cable trays or secured to supports not greater than 6 feet apart.
C-L-X Type MC-HL cables are also approved for Classes I , II , and III , Division 1 and 2 and Class I , Zones 1 and 2 hazardous locations - NEC Articles 501, 502, 503 and 505

Insulation
Okoguard Is Okonite's registered trade name for its exclusive ethylene-propylene rubber (EPR) base, thermosetting compound, whose optimum balance of electrical and physical properties is unequaled in other solid dielectrics. Okoguard insulation, with the distinctive red color and a totally integrated EPR system, provides the optimum balance of electrical and physical properties for long, problem free service.

Assembly

Type MV-105 conductors are assembled with fillers, three bare stranded grounding conductors and a binder tape into a round core. A continuously corrugated welded aluminum sheath (C-L-X) encases the cable core. The C-L-X sheath is protected with a low temperature yellow Okoseal® jacket. The impervious, continuous, corrugated aluminum C-L-X sheath provides complete protection against moisture, liquids and gases in addition to its excellent mechanical strength. In addition, the aluminum sheath has adequate ampacity capability to be used as a grounding conductor in non HL areas. The Okoseal jacket allows the cable to be direct buried in the ground, embedded in concrete or areas subjected to corrosive atmospheres.

Specifications

Conductors: Uncoated copper compact stranded per ASTM B-496.
Strand Screen: Extruded semiconducting EPR strand screen meets or exceeds electrical and physical requirements of ICEA S-96-659/NEMA WC71 and UL 1072.
Insulation: Okoguard meets or exceeds the electrical and physical requirements of ICEA S-96-659/NEMA WC71 and UL 1072. The insulated conductors are tested in accordance with AEIC CS8.
Insulation Screen: Extruded semiconducting EPR insulation screen per ICEA
S-93-639/NEMA WC74, AEIC CS8 and UL 1072.
Shield: 5 mil uncoated copper tape helically applied with 12.5% nominal overlap.
Phase Identification: Color coded (black, red, blue) polyester ribbon laid longitudinally under the copper shield tape.
Grounding Conductors: Three uncoated copper Class B in accordance with UL 1072.
Assembly: Cabled with fillers and ground wires, in the interstices, binder tape overall.
Sheath: Close fitting, impervious, continuous, corrugated aluminum C-L-X per UL 1072. C-L-X is recognized as a grounding conductor by NEC.
Jacket: A low temperature sunlight resistant, yellow PVC jacket in accordance with
UL 1072. Other color jackets are available.
UL Listed as type MV-105 or MC-HL, sunlight resistant for use in cable tray, and for direct burial in accordance with UL 1072 & 2225. CSA Listed to C68.3

Product Features

  • Tandem extruded, all EPR system.
  • Complete prepackaged, color coded, factory tested wiring system.
  • Okoguard CLX cables wire meet or exceed electrical and physical requirements of all recognized industry standards (UL, AEIC, NEMA/ICEA, IEEE).
  • Passes the vertical tray flame test requirements of IEEE 383 and 1202, UL 1072, ICEA T-29-520(210,000 BTU/hr.)
  • Complies with NEC Sections 310-7 and 300-50 for direct burial.
  • Complies with NEC Articles 501, 502, 503 and 505 for hazardous locations.
  • Continuous sheath provides grounding safety.
  • Excellent corona resistance.
  • Exceptional resistance to “treeing.”
  • Stress cones not required.
  • Minimum installation temperature of -40°C.
  • Three symmetrical grounding conductors for PWM/VFD and other modern AC drive/motor applications.
  • ABS listed as CWCMC Type MC-HL
  • CSA listed as FT4 and LTGG (-40°C)
  Product Name
Length
Price (Per FT.)
 
C-L-X Type MV-105 or MC-HL - Yellow Jacket

571-22-3694 C-L-X Type MV-105 or MC-HL - 8 AWG - Yellow Jacket

FT.
Call 516-472-0650 for pricing
C-L-X Type MV-105 or MC-HL - Yellow Jacket

571-22-3696 C-L-X Type MV-105 or MC-HL - 6 AWG - Yellow Jacket

FT.
Call 516-472-0650 for pricing
C-L-X Type MV-105 or MC-HL - Yellow Jacket

571-22-3698 C-L-X Type MV-105 or MC-HL - 4 AWG - Yellow Jacket

FT.
Call 516-472-0650 for pricing
C-L-X Type MV-105 or MC-HL - Yellow Jacket

571-22-3706 C-L-X Type MV-105 or MC-HL - 2 AWG - Yellow Jacket

FT.
Call 516-472-0650 for pricing
C-L-X Type MV-105 or MC-HL - Yellow Jacket

571-22-3708 C-L-X Type MV-105 or MC-HL - 1 AWG - Yellow Jacket

FT.
Call 516-472-0650 for pricing
C-L-X Type MV-105 or MC-HL - Yellow Jacket

571-22-3710 C-L-X Type MV-105 or MC-HL - 1/0 AWG - Yellow Jacket

FT.
Call 516-472-0650 for pricing
C-L-X Type MV-105 or MC-HL - Yellow Jacket

571-22-3717 C-L-X Type MV-105 or MC-HL - 2/0 AWG - Yellow Jacket

FT.
Call 516-472-0650 for pricing
C-L-X Type MV-105 or MC-HL - Yellow Jacket

571-22-3725 C-L-X Type MV-105 or MC-HL - 4/0 AWG - Yellow Jacket

FT.
Call 516-472-0650 for pricing
C-L-X Type MV-105 or MC-HL - Yellow Jacket

571-22-3727 C-L-X Type MV-105 or MC-HL - 250 MCM AWG - Yellow Jacket

FT.
Call 516-472-0650 for pricing
C-L-X Type MV-105 or MC-HL - Yellow Jacket

571-22-3838 C-L-X Type MV-105 or MC-HL - 350 MCM AWG - Yellow Jacket

FT.
Call 516-472-0650 for pricing
C-L-X Type MV-105 or MC-HL - Yellow Jacket

571-22-3846 C-L-X Type MV-105 or MC-HL - 500 MCM AWG - Yellow Jacket

FT.
Call 516-472-0650 for pricing
C-L-X Type MV-105 or MC-HL - Yellow Jacket

571-22-3748 C-L-X Type MV-105 or MC-HL - 750 MCM AWG - Yellow Jacket

FT.
Call 516-472-0650 for pricing
C-L-X Type MV-105 or MC-HL - Yellow Jacket

571-22-3751 C-L-X Type MV-105 or MC-HL - 1000 MCM AWG - Yellow Jacket

FT.
Call 516-472-0650 for pricing

Specification

Applications

C-L-X power cables are recommended as an economical alternate to a wire in conduit system. They are designed specifically for use as feeders or branch circuits in industrial and utility power distribution systems. C-L-X power cables may be installed in both exposed and concealed work, wet and dry locations, directly buried in the earth, or embedded in concrete. They may be installed on metal racks, troughs, in cable trays or secured to supports not greater than 6 feet apart.
C-L-X Type MC-HL cables are also approved for Classes I , II , and III , Division 1 and 2 and Class I , Zones 1 and 2 hazardous locations - NEC Articles 501, 502, 503 and 505

Details

C-L-X Type MV-105 or MC-HL - Yellow Jacket Cable

This type of Multi-conductor power cable is yellow color coded for easy identification. C-L-X is instilled with filers, three grounding conductors which are left bare and wrapped with a binding tape to form the round core. The core is encased with the CCW (Continuously Corrugated Welded) aluminum sheath, which is covered by the low temperature yellow jacket.

Conductor

This Type MV-105 power cable has three conductors, which are made of copper. The conductors do not exceed 10 feet long. These conductors are compacted and stranded according to the ASTM B496 requirements. Stranding of the conductors improves the flexibility of this cable, whereas compacting makes them creep resistant. Copper is one of the best electrical conductors and thus provides superb performance on the C-L-X Power Cable.

Standards and Certifications

The C-L-X Power Cable is tested and approved to be in line with all the necessary international standards organizations, which include the following:

• AIC CS8
• Underwriters Laboratory (UL) 1072
• ASTM B496
• ICEA S-96-659
• NEMA WC71
• National Electrical Code (NEC) Article 501, 502 & 503
• CSA Listed to C68.3
• IEEE 383 & 1202
• ICEA T-29-520
• ABS listed as CWCMC Type MC-HL

Insulation

C-L-X Power Cable is insulated with the semiconducting Ethylene Propylene Rubber (EPR). This protects the handler from electric shocks when handling the cable. EPR also improves the service life as it protects it from chemical and mechanical damages like chlorides, abrasion, creeping or any other deformations.

Shielding

The cable is shielded with a 5 mil bare copper tape that is applied helically. It has a 12.5% nominal overlap and holds the conductors in positions.

Jacketing

It is jacketed with a low temperature PVC which is yellow colored. The PVC protects the cable from damages in the harsh environmental conditions. These damages include; flames, abrasions, moisture, chloride chemicals and oil.

Applications

C-L-X power cable is installed in both wet and dry locations. It is meant for use as feeders and branch circuits for industrial and utility systems. The cable can be installed through direct burial, cable trays, troughs and raceways.

Write Your Own Review

You're reviewing: C-L-X Type MV-105 or MC-HL - Yellow Jacket

How do you rate this product? *

 
1 1 star
2 2 star
3 3 star
4 4 star
5 5 star
Price
Value
Quality