C-L-X Type MV-90 or MC-HL

C-L-X Type MV-90 or MC-HL
Specification

Applications

C-L-X power cables are recommended as an economical alternate to a wire in conduit system. They are designed specifically for use on feeders and branch circuits in industrial power distribution systems. C-L-X power cables may be installed in both exposed and concealed work, wet and dry locations, direct burial in the earth, or embedded in concrete. They may be installed on metal racks, troughs, in cable trays or secured to supports not greater than 6 feet apart. C-L-X power cables are also approved for Classes I, II and III. Divisions 1 and 2 and Class I, Zones 1 and 2 hazardous locations - NEC Articles 501, 502, 503 and 505. Medium voltage Non-Shielded cables discharge normally in service when spacing between phases is non-uniform or when phases are in close proximity to a grounded surface.

Insulation
Okoguard Is Okonite's registered trade name for its exclusive ethylene-propylene rubber (EPR) base, thermosetting compound, whose optimum balance of electrical and physical properties is unequaled in other solid dielectrics. Okoguard insulation, with the distinctive red color and a totally integrated EPR system, provides the optimum balance of electrical and physical properties for long, problem free service.

Assembly

The Type MV-90 conductors are assembled with fillers and a binder tape into a round core.Three bare stranded copper grounding conductors, located in the outer interstices, is provided for grounding. A continuously corrugated welded aluminum sheath C-L-X encases the cable core. The C-L-X sheath is protected with a low temperature yellow Okoseal® (PVC) jacket. The impervious, continuous, corrugated aluminum C-L-X sheath provides complete protection against moisture, liquids and gases in addition to its excellent mechanical strength. Also, the aluminum C-L-X sheath has adequate ampacity capability to be used as a grounding conductor. The overall Okoseal (PVC) jacket allows the cable to be direct buried in the ground, embedded in concrete or areas subjected to a corrosive atmosphere.

Specifications

Conductors: Annealed uncoated copper compact stranded per ASTM B-496.
Strand Screen: Extruded semiconducting EPR strand screen meets or exceeds electrical and physical requirements of ICEA S-96-659/NEMA WC71 and UL 1072.
Insulation: Okoguard meets or exceeds the electrical and physical requirements of ICEA S-96-659/NEMA WC71 and UL 1072.
Phase Identification: Print color code (black, red and blue).
Grounding Conductors: Three uncoated copper Class B in accordance with UL 1072.
Assembly: Cabled with fillers and ground wires, in the interstices, binder tape overall.
Sheath: Close fitting, impervious, continuous, corrugated aluminum C-L-X per UL 1072. C-L-X is recognized as a grounding conductor by NEC.
Jacket: A low temperature sunlight resistant, yellow PVC jacket in accordance with
UL 1072. Other color jackets are available.
UL Listed as type MV-90 or MC-HL, sunlight resistant, for use in cable tray, and for direct burial in accordance with UL 1072 and 2225.

Product Features

  • Tandem extruded, all EPR system.
  • Complete prepackaged, color coded, factory tested wiring system.
  • Okoguard C-L-X cables meet or exceed electrical and physical requirements of all recognized industry standards (UL, AEIC, NEMA/ICEA, IEEE).
  • Passes the vertical tray flame test requirements of IEEE 383 and 1202, UL 1072, ICEA T-29-520(210,000 BTU/hr.)
  • Complies with NEC Sections 310-7 and 300-50 for direct burial.
  • Complies with NEC Articles 501, 502, 503 and 505 for hazardous locations.
  • Continuous sheath provides grounding safety.
  • Excellent corona resistance.
  • Exceptional resistance to “treeing.”
  • Stress cones not required.
  • Minimum installation temperature of -40°C.
  • Three symmetrical grounding conductors for PWM/VFD and other modern AC drive/motor applications.
  • ABS listed as CWCMC Type MC-HL
  • CSA listed as RA90, FT4, SR, HL, -40°C and 5000V
  Product Name
Length
Price (Per FT.)
 
C-L-X Type MV-90 or MC-HL

571-21-3193 C-L-X Type MV-90 or MC-HL - 8 AWG

FT.
Call 516-472-0650 for pricing
C-L-X Type MV-90 or MC-HL

571-21-3196 C-L-X Type MV-90 or MC-HL - 6 AWG

FT.
Call 516-472-0650 for pricing
C-L-X Type MV-90 or MC-HL

571-21-3200 C-L-X Type MV-90 or MC-HL - 4 AWG

FT.
Call 516-472-0650 for pricing
C-L-X Type MV-90 or MC-HL

571-21-3204 C-L-X Type MV-90 or MC-HL - 2 AWG

FT.
Call 516-472-0650 for pricing
C-L-X Type MV-90 or MC-HL

571-21-3208 C-L-X Type MV-90 or MC-HL - 1 AWG

FT.
Call 516-472-0650 for pricing
C-L-X Type MV-90 or MC-HL

571-21-3212 C-L-X Type MV-90 or MC-HL - 1/0 AWG

FT.
Call 516-472-0650 for pricing
C-L-X Type MV-90 or MC-HL

571-21-3217 C-L-X Type MV-90 or MC-HL - 2/0 AWG

FT.
Call 516-472-0650 for pricing
C-L-X Type MV-90 or MC-HL

571-21-3224 C-L-X Type MV-90 or MC-HL - 4/0 AWG

FT.
Call 516-472-0650 for pricing
C-L-X Type MV-90 or MC-HL

571-21-3228 C-L-X Type MV-90 or MC-HL - 250 MCM AWG

FT.
Call 516-472-0650 for pricing
C-L-X Type MV-90 or MC-HL

571-21-3236 C-L-X Type MV-90 or MC-HL - 350 MCM AWG

FT.
Call 516-472-0650 for pricing
C-L-X Type MV-90 or MC-HL

571-21-3244 C-L-X Type MV-90 or MC-HL - 500 MCM AWG

FT.
Call 516-472-0650 for pricing
C-L-X Type MV-90 or MC-HL

571-21-3248 C-L-X Type MV-90 or MC-HL - 750 MCM AWG

FT.
Call 516-472-0650 for pricing
C-L-X Type MV-90 or MC-HL

571-21-3252 C-L-X Type MV-90 or MC-HL - 1000 MCM AWG

FT.
Call 516-472-0650 for pricing

Specification

Applications

C-L-X power cables are recommended as an economical alternate to a wire in conduit system. They are designed specifically for use on feeders and branch circuits in industrial power distribution systems. C-L-X power cables may be installed in both exposed and concealed work, wet and dry locations, direct burial in the earth, or embedded in concrete. They may be installed on metal racks, troughs, in cable trays or secured to supports not greater than 6 feet apart. C-L-X power cables are also approved for Classes I, II and III. Divisions 1 and 2 and Class I, Zones 1 and 2 hazardous locations - NEC Articles 501, 502, 503 and 505. Medium voltage Non-Shielded cables discharge normally in service when spacing between phases is non-uniform or when phases are in close proximity to a grounded surface.

Details

C-L-X Type MV-90 OR MC-HL

This is a type of multi-conductor cable designed with an operational voltage rating of 90 volts. It is made of three copper conductors which are insulated with an Ethylene Propylene Rubber (EPR). The cable is shielded with copper tape and sheathed with the Continuously Corrugated Welded (CCW) for maximum protection. C-L-X Type MV-90 cable has a minimum installation temperature rating of -400C.

Conductor

The cable is made of compacted and annealed copper conductors as per ASTM B496 standards. It measures 4 AWG (American Wire Gauge) and ten feet long. Annealing is the process of heating the copper conductors and allowing them to cool; it makes them more soft and malleable without interfering with their good electrical conductive properties. This improves the flexibility aspect of Type MV-90 C-L-X cable. Flexible multi-conductor power cables are easy to install as they require less effort to twist and fold.

Standards and Certifications

C-L-X Type MV-90 power cable is approved to serve its intended purpose in line with the requirements of the following international organizations standards:

• ASTM B496
• Underwriters Laboratory (UL) 1072
• ICEA S-96-659
• NEMA WC71
• CSA listed as RA90
• IEEE 383
• National Electrical Code (NEC) Article 501, 502, 503 and 505

Insulation

The cable’s insulation is made of Ethylene Propylene Rubber. EPR is a semiconductor and protects the user from risks like electrocution when installing or handling the cable. The EPR also improves the safety of this cable by protecting it from the punishing environmental conditions such as; strong sunlight radiations, corrosive industrial chemicals and deformations. This makes the cable durable.

Jacketing

Tough Polyvinyl Chloride with low temperature tolerance, offers a superb chemical and mechanical protection to this cable. It is yellow color coded for easy identification.

Applications

C-L-X Type MV-90 power cable is economical alternate to wires in conduit systems. Thanks to the Continuously Corrugated Welded aluminum sheath. This cable is designed to help in power distributions for 90 volts wiring systems. It is desirable for use in feeders and branch circuiting for:

• Industrial motors
• Heavy engines
• Heating facilities

Write Your Own Review

You're reviewing: C-L-X Type MV-90 or MC-HL

How do you rate this product? *

 
1 1 star
2 2 star
3 3 star
4 4 star
5 5 star
Price
Value
Quality