Loxarmor Type MV-90 or MC - Galvanized Steel

Loxarmor Type MV-90 or MC - Galvanized Steel
Specification

Applications

Loxarmor power cables are recommended as an economical alternate to a wire in conduit system. They are designed specifically for use on feeders and branch circuits in industrial power distribution systems. Loxarmor power cables may be installed in both exposed and concealed work, wet and dry location, direct burial in the earth, or embedded in concrete. They may be installed on metal racks, troughs, in cable trays or secured to supports not greater than 6 feet apart. Loxarmor power cables are also approved for Classes I and II, Division 2 and Class III, Divisions 1 and 2, hazardous locations - NEC Articles 501, 502 and 503.
2.4kV Non-Shielded cables discharge normally in service when spacing between phases is non-uniform or when phases are in close proximity to a grounded surface.

  Product Name
Length
Price (Per FT.)
 

114-24-5341 Loxarmor Type MV-90 or MC - Galvanized Steel - 8 AWG

FT.
Call 516-472-0650 for pricing

114-24-5342 Loxarmor Type MV-90 or MC - Galvanized Steel - 6 AWG

FT.
Call 516-472-0650 for pricing

114-24-5343 Loxarmor Type MV-90 or MC - Galvanized Steel - 4 AWG

FT.
Call 516-472-0650 for pricing

114-24-5344 Loxarmor Type MV-90 or MC - Galvanized Steel - 2 AWG

FT.
Call 516-472-0650 for pricing

114-24-5345 Loxarmor Type MV-90 or MC - Galvanized Steel - 1 AWG

FT.
Call 516-472-0650 for pricing

114-24-5346 Loxarmor Type MV-90 or MC - Galvanized Steel - 1/0 AWG

FT.
Call 516-472-0650 for pricing

114-24-5347 Loxarmor Type MV-90 or MC - Galvanized Steel - 2/0 AWG

FT.
Call 516-472-0650 for pricing

114-24-5348 Loxarmor Type MV-90 or MC - Galvanized Steel - 4/0 AWG

FT.
Call 516-472-0650 for pricing

114-24-5349 Loxarmor Type MV-90 or MC - Galvanized Steel - 250 MCM AWG

FT.
Call 516-472-0650 for pricing

114-24-5350 Loxarmor Type MV-90 or MC - Galvanized Steel - 350 MCM AWG

FT.
Call 516-472-0650 for pricing

114-24-5351 Loxarmor Type MV-90 or MC - Galvanized Steel - 500 MCM AWG

FT.
Call 516-472-0650 for pricing

114-24-5352 Loxarmor Type MV-90 or MC - Galvanized Steel - 750 MCM AWG

FT.
Call 516-472-0650 for pricing

114-24-5353 Loxarmor Type MV-90 or MC - Galvanized Steel - 1000 MCM AWG

FT.
Call 516-472-0650 for pricing

Specification

Applications

Loxarmor power cables are recommended as an economical alternate to a wire in conduit system. They are designed specifically for use on feeders and branch circuits in industrial power distribution systems. Loxarmor power cables may be installed in both exposed and concealed work, wet and dry location, direct burial in the earth, or embedded in concrete. They may be installed on metal racks, troughs, in cable trays or secured to supports not greater than 6 feet apart. Loxarmor power cables are also approved for Classes I and II, Division 2 and Class III, Divisions 1 and 2, hazardous locations - NEC Articles 501, 502 and 503.
2.4kV Non-Shielded cables discharge normally in service when spacing between phases is non-uniform or when phases are in close proximity to a grounded surface.

Details

Insulation
Okoguard Is Okonite's registered trade name for its exclusive ethylene-propylene rubber (EPR) base, thermosetting compound, whose optimum balance of electrical and physical properties is unequaled in other solid dielectrics. Okoguard insulation, with the distinctive red color and a totally integrated EPR system, provides the optimum balance of electrical and physical properties for long, problem free service.

Assembly

The Type MV-90 conductors are assembled with fillers and a binder tape overall. One bare stranded copper grounding conductor is placed in one of the outer interstices. The interlocked armor provides good mechanical strength. For direct burial, embedment in concrete or for areas subjected to corrosive atmospheres, the Loxarmor is protected with a yellow Okoseal® (PVC) jacket.

Specifications

Conductors: Uncoated copper compact stranded per ASTM B-496.
Strand Screen: Extruded semiconducting EPR strand screen meets or exceeds electrical and physical requirements of ICEA S-96-659/NEMA WC71 and UL 1072.
Insulation: Okoguard meets or exceeds the electrical and physical requirements of ICEA S-96-659/NEMA WC71 and UL 1072. The insulated conductors are tested in accordance with AEIC CS8.
Insulation Screen: Extruded semiconducting EPR insulation screen per ICEA
S-93-639/NEMA WC74, AEIC CS8 and UL 1072.
Shield: 5 mil uncoated copper tape helically applied with 12.5% nominal overlap.
Phase Identification: Color coded (black, red, blue) polyester ribbon laid longitudinally under the copper shield tape.
Grounding Conductors: Three uncoated copper Class B in accordance with UL 1072.
Assembly: Cabled with fillers and ground wires, in the interstices, binder tape overall.
Loxarmor: Galvanized steel or aluminum interlocked tape armor per UL 1072, ICEA S-96-659 NEMA WC71, and UL Listing E-60545.
Jacket: Sunlight resistant, yellow PVC jacket in accordance with UL 1072. UL Listed as Type MV-90 or MC, sunlight resistant, for use in cable tray, and for direct burial in accordance with UL 1072.

Product Features

  • Tandem extruded, all EPR system.
  • Complete prepackaged, color coded, factory tested wiring system.
  • Okoguard Loxarmor cables meet or exceed all recognized industry standards (UL, AEIC, NEMA/ICEA, IEEE).
  • Passes the vertical tray flame test requirements of IEEE 383 and 1202, UL 1072, ICEA T-29-520(210,000 BTU/hr.)
  • Complies with NEC Sections 310-7 and 300-50 for direct burial.
  • Excellent corona resistance.
  • Exceptional resistance to “treeing.”
  • Stress cones not required.
  • Resistant to most oils, acids, and alkalies.
  • Minimum installation temperature of -40°C.