Okoguard-Okoseal Type MV-105 - For Cable Tray Use

Okoguard-Okoseal Type MV-105 - For Cable Tray Use
Specification
.

Applications
Okoguard shielded Okoseal Type MV-105 power cables are recommended for use as feeder circuits, in electric utility generating stations, for distribution circuits, and for feeders or branch circuits in industrial and commercial installations.
Type MV cables may be installed in wet or dry locations, indoors or outdoors (exposed to sunlight), in any raceway or underground duct, directly buried if installed in a system with a grounding conductor in close proximity that conforms with NEC Section 250.4(A)(5), or messenger supported in industrial establishments and electric utilities. Sizes 1/0 AWG and larger may also be installed in cable tray.

  Product Name
Length
Price (Per FT.)
 

114-23-3824 Okoguard-Okoseal Type MV-105 - 1/0 AWG - For Cable Tray Use

FT.
Call 516-472-0650 for pricing

114-23-3826 Okoguard-Okoseal Type MV-105 - 2/0 AWG - For Cable Tray Use

FT.
Call 516-472-0650 for pricing

114-23-3865 Okoguard-Okoseal Type MV-105 - 3/0 AWG - For Cable Tray Use

FT.
Call 516-472-0650 for pricing

114-23-3832 Okoguard-Okoseal Type MV-105 - 4/0 AWG - For Cable Tray Use

FT.
Call 516-472-0650 for pricing

114-23-3834 Okoguard-Okoseal Type MV-105 - 250 MCM AWG - For Cable Tray Use

FT.
Call 516-472-0650 for pricing

114-23-3838 Okoguard-Okoseal Type MV-105 - 350 MCM AWG - For Cable Tray Use

FT.
Call 516-472-0650 for pricing

114-23-3846 Okoguard-Okoseal Type MV-105 - 500 MCM AWG - For Cable Tray Use

FT.
Call 516-472-0650 for pricing

114-23-3873 Okoguard-Okoseal Type MV-105 - 750 MCM AWG - For Cable Tray Use

FT.
Call 516-472-0650 for pricing

114-23-3855 Okoguard-Okoseal Type MV-105 - 1000 MCM AWG - For Cable Tray Use

FT.
Call 516-472-0650 for pricing

Specification

.

Applications
Okoguard shielded Okoseal Type MV-105 power cables are recommended for use as feeder circuits, in electric utility generating stations, for distribution circuits, and for feeders or branch circuits in industrial and commercial installations.
Type MV cables may be installed in wet or dry locations, indoors or outdoors (exposed to sunlight), in any raceway or underground duct, directly buried if installed in a system with a grounding conductor in close proximity that conforms with NEC Section 250.4(A)(5), or messenger supported in industrial establishments and electric utilities. Sizes 1/0 AWG and larger may also be installed in cable tray.

Details

Insulation
Okoguard is Okonite's registered trade name for its exclusive ethylene-propylene rubber (EPR) based, thermosetting compound, whose optimum balance of electrical and physical properties is unequaled in other solid dielectrics.
Okoguard insulation, with the distinctive red color and a totally integrated EPR system, provides the optimum balance of electrical and physical properties for long, problem free service.
The triple tandem extrusion of the screens with the insulation provides optimum electrical characteristics.

Jacket
The Okoseal (PVC) jacket supplied with this cable is mechanically rugged and has excellent resistance to oil, acids and most chemicals.

Specifications
Conductor: Annealed uncoated copper compact stranded per ASTM B-496.
Strand Screen: Extruded semiconducting EPR strand screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639/NEMA WC74 & S-97-682, AEIC CS8, CSA C68.3 and UL 1072.
Insulation: Meets or exceeds electrical and physical requirements of ICEA S-93- 639/NEMA WC74 & S-97-682, AEIC CS8, CSA C68.3 and UL 1072.
Insulation Screen: Extruded semiconducting EPR insulation screen applied directly over the insulation. Meets or exceeds electrical and physical requirements of ICEA S-93-639/NEMA WC74 & S-97-682, AEIC CS8, CSA C68.3 and UL 1072.
Shield: 5 mil bare copper tape helically applied with 25% minimum overlap.
Jacket: Meets or exceeds electrical and physical requirements of ICEA S-93-639/NEMA WC74 & S-97-682, CSA C68.3 and UL 1072 for polyvinyl chloride jackets.
UL Listed as Type MV-105 and sunlight resistant, in accordance with UL 1072.
CSA C68.3 listed and rated FT4.

Product Features

  • Triple tandem extruded, all EPR system.
  • Okoguard cables meet or exceed all recognized industry standards (UL, AEIC, NEMA/ICEA, IEEE).
  • 105?C continuous operating temperature.
  • 140?C emergency rating.
  • 250?C short circuit rating.
  • Passes UL and IEEE 383 and 1202 (1/0 AWG and larger) Vertical Tray Flame Test.
  • Excellent corona resistance.
  • Screens are clean stripping.
  • Exceptional resistance to ?treeing?.
  • Exceptional resistance to moisture.
  • Resistant to most oils, acids, and alkalies.
  • Sunlight resistant.
  • For Cable Tray Use.
  • CSA FT4.
  • CSA≤350: LTDD (-25C)
  • CSA≥500: LTGG (-40C)
  • Improved Temperature Rating.

Write Your Own Review

You're reviewing: Okoguard-Okoseal Type MV-105 - For Cable Tray Use

How do you rate this product? *

 
1 1 star
2 2 star
3 3 star
4 4 star
5 5 star
Price
Value
Quality