Okonite-FMR-N Okolon TS-CPE - 2000V

Okonite-FMR-N Okolon TS-CPE - 2000V
Specification

Applications
Okonite FMR-N Control Cables are recommended for use in either power generating plants and in substations; designed especially for critical circuits where continuity of service is of prime importance. This premium quality control cable is recommended for wet or dry, ac or dc service at conductor temperatures to 90°C. They may be installed in conduits, ducts, cable troughs, trays, messenger supported, or directly buried in the earth.

  Product Name
Length
Price (Per FT.)
 

202-18-2153 Okonite-FMR-N Okolon TS-CPE - 2000V - 14 AWG - 3 Conductors

FT.
Call 516-472-0650 for pricing

202-18-2154 Okonite-FMR-N Okolon TS-CPE - 2000V - 14 AWG - 4 Conductors

FT.
Call 516-472-0650 for pricing

202-18-2155 Okonite-FMR-N Okolon TS-CPE - 2000V - 14 AWG - 5 Conductors

FT.
Call 516-472-0650 for pricing

202-18-2157 Okonite-FMR-N Okolon TS-CPE - 2000V - 14 AWG - 7 Conductors

FT.
Call 516-472-0650 for pricing

202-18-2159 Okonite-FMR-N Okolon TS-CPE - 2000V - 14 AWG - 9 Conductors

FT.
Call 516-472-0650 for pricing

202-18-2162 Okonite-FMR-N Okolon TS-CPE - 2000V - 14 AWG - 12 Conductors

FT.
Call 516-472-0650 for pricing

202-18-2169 Okonite-FMR-N Okolon TS-CPE - 2000V - 14 AWG - 19 Conductors

FT.
Call 516-472-0650 for pricing

202-18-2187 Okonite-FMR-N Okolon TS-CPE - 2000V - 14 AWG - 37 Conductors

FT.
Call 516-472-0650 for pricing

202-18-2302 Okonite-FMR-N Okolon TS-CPE - 2000V - 12 AWG - 2 Conductors

FT.
Call 516-472-0650 for pricing

202-18-2303 Okonite-FMR-N Okolon TS-CPE - 2000V - 12 AWG - 3 Conductors

FT.
Call 516-472-0650 for pricing

202-18-2304 Okonite-FMR-N Okolon TS-CPE - 2000V - 12 AWG - 4 Conductors

FT.
Call 516-472-0650 for pricing

202-18-2305 Okonite-FMR-N Okolon TS-CPE - 2000V - 12 AWG - 5 Conductors

FT.
Call 516-472-0650 for pricing

202-18-2307 Okonite-FMR-N Okolon TS-CPE - 2000V - 12 AWG - 7 Conductors

FT.
Call 516-472-0650 for pricing

202-18-2309 Okonite-FMR-N Okolon TS-CPE - 2000V - 12 AWG - 9 Conductors

FT.
Call 516-472-0650 for pricing

202-18-2312 Okonite-FMR-N Okolon TS-CPE - 2000V - 12 AWG - 12 Conductors

FT.
Call 516-472-0650 for pricing

202-18-2319 Okonite-FMR-N Okolon TS-CPE - 2000V - 12 AWG - 19 Conductors

FT.
Call 516-472-0650 for pricing

202-18-2337 Okonite-FMR-N Okolon TS-CPE - 2000V - 12 AWG - 37 Conductors

FT.
Call 516-472-0650 for pricing

202-18-2452 Okonite-FMR-N Okolon TS-CPE - 2000V - 10 AWG - 2 Conductors

FT.
Call 516-472-0650 for pricing

202-18-2453 Okonite-FMR-N Okolon TS-CPE - 2000V - 10 AWG - 3 Conductors

FT.
Call 516-472-0650 for pricing

202-18-2454 Okonite-FMR-N Okolon TS-CPE - 2000V - 10 AWG - 4 Conductors

FT.
Call 516-472-0650 for pricing

202-18-2455 Okonite-FMR-N Okolon TS-CPE - 2000V - 10 AWG - 5 Conductors

FT.
Call 516-472-0650 for pricing

202-18-2457 Okonite-FMR-N Okolon TS-CPE - 2000V - 10 AWG - 7 Conductors

FT.
Call 516-472-0650 for pricing

202-18-2459 Okonite-FMR-N Okolon TS-CPE - 2000V - 10 AWG - 9 Conductors

FT.
Call 516-472-0650 for pricing

202-18-2462 Okonite-FMR-N Okolon TS-CPE - 2000V - 10 AWG - 12 Conductors

FT.
Call 516-472-0650 for pricing

202-18-2652 Okonite-FMR-N Okolon TS-CPE - 2000V - 9 AWG - 2 Conductors

FT.
Call 516-472-0650 for pricing

202-18-2653 Okonite-FMR-N Okolon TS-CPE - 2000V - 9 AWG - 3 Conductors

FT.
Call 516-472-0650 for pricing

202-18-2654 Okonite-FMR-N Okolon TS-CPE - 2000V - 9 AWG - 4 Conductors

FT.
Call 516-472-0650 for pricing

202-18-2655 Okonite-FMR-N Okolon TS-CPE - 2000V - 9 AWG - 5 Conductors

FT.
Call 516-472-0650 for pricing

202-18-2657 Okonite-FMR-N Okolon TS-CPE - 2000V - 9 AWG - 7 Conductors

FT.
Call 516-472-0650 for pricing

202-18-2659 Okonite-FMR-N Okolon TS-CPE - 2000V - 9 AWG - 9 Conductors

FT.
Call 516-472-0650 for pricing

202-18-2662 Okonite-FMR-N Okolon TS-CPE - 2000V - 9 AWG - 12 Conductors

FT.
Call 516-472-0650 for pricing

Specification

Applications
Okonite FMR-N Control Cables are recommended for use in either power generating plants and in substations; designed especially for critical circuits where continuity of service is of prime importance. This premium quality control cable is recommended for wet or dry, ac or dc service at conductor temperatures to 90°C. They may be installed in conduits, ducts, cable troughs, trays, messenger supported, or directly buried in the earth.

Details

Insulation
Okonite FMR-N is Okonite’s trade name for its heat, moisture, flame and chemically resistant, mechanically rugged nuclear plant qualified ethylene-propylene insulation compound. Its physical properties and flame retardency permit its use without a jacket on the single conductors.
The properties of Okonite FMR-N insulation substantially enhance the well known features of ethylene propylene rubber insulations.
Nuclear qualified Okonite FMR-N cables meet IEEE Standard - 383 LOCA and flame test criteria.

Overall Jacket
The overall Okolon TS-CPE jacket is a thermoset chlorinated polyethylene compound. This combination construction assures circuit security because of its high mechanical strength and excellent resistance to moisture, ozone, oil and most chemicals.

Specifications
Conductors: Copper per ASTM B-3, Class B stranded per ASTM B-8.
Insulation: Okonite FMR-N meets or exceeds the electrical and physical requirements of ICEA S-73-532.
Color Coding: Base colors and tracers per ICEA Method 1 Table E-1 color sequence shown on reverse of this sheet.
Asembly: Conductors cabled using flame and moisture resistant fillers.
Overall Jacket: The Okolon TS-CPE compound meets or exceeds the requirements of ICEA S-73-532

Product Features

  • Qualified as Class 1E cable
  • Flame retardant - passes the IEEE 383 and 1202 flame test requirements.
  • Quality Assurance traceability
  • 90°C rated control cable, factory assembled for indoor or outdoor installation in cable trays, in raceways, direct burial in the earth, or supported by messenger wire.
  • Mechanically rugged.
  • Flexible, easy to install and terminate.
  • Color coded conductors.
  • Resistant to water, oil and most chemicals.
  • Thermally stable at elevated temperatures.
  • High insulation resistance, even at elevated temperatures.
  • Small diameter, lightweight.

Write Your Own Review

You're reviewing: Okonite-FMR-N Okolon TS-CPE - 2000V

How do you rate this product? *

 
1 1 star
2 2 star
3 3 star
4 4 star
5 5 star
Quality
Price
Value