Okonite-FMR

Okonite-FMR
Specification

Applications
Okonite-FMR Type RHH or RHW-2 600 Volt Power and Control Cables are recommended for general low voltage power and control applications. Okonite-FMR flame retardant insulated power cables may be used in generating plants, substations and industrial plants. Type RHH or RHW-2 may be used up to 90°C in dry or wet locations. These cables may be installed in wet or dry locations, indoors or outdoors, in raceways, underground ducts, cable tray (size 1/0 AWG and larger per NEC 392) or lashed to a messenger for aerial installation.

  Product Name
Length
Price (Per FT.)
 

112-09-1061 Okonite-FMR Type RHH or RHW-2,VW-1 - 14 AWG - 1 Strand

FT.
Call 516-472-0650 for pricing

112-09-1071 Okonite-FMR Type RHH or RHW-2,VW-1 - 14 AWG - 7 Strands

FT.
Call 516-472-0650 for pricing

112-09-1091 Okonite-FMR Type RHH or RHW-2,VW-1 - 12 AWG - 1 Strand

FT.
Call 516-472-0650 for pricing

112-09-1101 Okonite-FMR Type RHH or RHW-2,VW-1 - 12 AWG - 7 Strands

FT.
Call 516-472-0650 for pricing

112-09-1121 Okonite-FMR Type RHH or RHW-2,VW-1 - 10 AWG - 1 Strand

FT.
Call 516-472-0650 for pricing

112-09-1131 Okonite-FMR Type RHH or RHW-2,VW-1 - 10 AWG - 7 Strands

FT.
Call 516-472-0650 for pricing

112-09-1191 Okonite-FMR Type RHH or RHW-2,VW-1 - 8 AWG - 7 Strands

FT.
Call 516-472-0650 for pricing

112-09-1221 Okonite-FMR Type RHH or RHW-2,VW-1 - 6 AWG - 7 Strands

FT.
Call 516-472-0650 for pricing

112-09-1251 Okonite-FMR Type RHH or RHW-2,VW-1 - 4AWG - 7 Strands

FT.
Call 516-472-0650 for pricing

112-09-1311 Okonite-FMR Type RHH or RHW-2,VW-1 - 2 AWG - 7 Strands

FT.
Call 516-472-0650 for pricing

112-09-1331 Okonite-FMR Type RHH or RHW-2,VW-1 - 1 AWG - 19 Strands

FT.
Call 516-472-0650 for pricing

112-09-1351 Okonite-FMR Type RHH or RHW-2,VW-1 - 1/0 AWG - 19 Strands

FT.
Call 516-472-0650 for pricing

112-09-1371 Okonite-FMR Type RHH or RHW-2,VW-1 - 2/0 AWG - 19 Strands

FT.
Call 516-472-0650 for pricing

112-09-1391 Okonite-FMR Type RHH or RHW-2,VW-1 - 3/0 AWG - 19 Strands

FT.
Call 516-472-0650 for pricing

112-09-1411 Okonite-FMR Type RHH or RHW-2,VW-1 - 4/0 AWG - 19 Strands

FT.
Call 516-472-0650 for pricing

112-09-1431 Okonite-FMR Type RHH or RHW-2,VW-1 - 250 MCM AWG - 37 Strands

FT.
Call 516-472-0650 for pricing

112-09-1471 Okonite-FMR Type RHH or RHW-2,VW-1 - 350 MCM AWG - 37 Strands

FT.
Call 516-472-0650 for pricing

112-09-1531 Okonite-FMR Type RHH or RHW-2,VW-1 - 500 MCM AWG - 37 Strands

FT.
Call 516-472-0650 for pricing

112-09-1591 Okonite-FMR Type RHH or RHW-2,VW-1 - 750 MCM AWG - 61 Strands

FT.
Call 516-472-0650 for pricing

112-09-1651 Okonite-FMR Type RHH or RHW-2,VW-1 - 1000 MCM AWG - 61 Strands

FT.
Call 516-472-0650 for pricing

Specification

Applications
Okonite-FMR Type RHH or RHW-2 600 Volt Power and Control Cables are recommended for general low voltage power and control applications. Okonite-FMR flame retardant insulated power cables may be used in generating plants, substations and industrial plants. Type RHH or RHW-2 may be used up to 90°C in dry or wet locations. These cables may be installed in wet or dry locations, indoors or outdoors, in raceways, underground ducts, cable tray (size 1/0 AWG and larger per NEC 392) or lashed to a messenger for aerial installation.

Details

Insulation
Okonite-FMR is Okonite’s trade name for its heat resistant, mechanically rugged black pigmented ethylene-propylene base insulating compound.

Specifications
Conductor:Uncoated soft copper per ASTM B-3. Solid per ASTM B-3. Sizes smaller than #8 are compress stranded per ASTM B-8. Sizes #8 and larger are compact stranded per ASTM B-496.
Insulation:Meets or exceeds all requirements of ICEA S-95-658, NEMA WC-70, IEEE Standard 383, and UL 44.
Listed by Underwriters Laboratories, Inc. as Type RHH or RHW-2, VW-1.

Product Features

  • Sizes 1/0 AWG and larger pass the Vertical Tray Flame Test requirements of UL 1581 for use in cable tray.
  • Passes the ICEA T-29-520 210,000 Btu/hr. vertical tray flame test (sizes 6 AWG and larger).
  • Passes the IEEE 383 Vertical Tray Flame Test.
  • Passes the IEEE 1202 Vertical Tray Flame Test. (sizes 1/0 AWG and larger).
  • Extreme heat resistance 90°C continuous rating; 130°C emergency overload rating; 250°C short circuit rating.
  • Rated 90°C wet or dry.
  • Exceptional resistance to deformation at high temperatures.
  • Stable electrical properties.
  • Low SIC and power factor.
  • Low moisture absorption.
  • Mechanically rugged.
  • Resistant to weather.
  • Smaller diameter.
  • More flexible, easier to install, terminate, or splice than XLPE insulation.
  • Flame retardant.
  • UL Listed, UL Rated VW-1.

Write Your Own Review