Type P-OS, Type ITC/PLTC, Single Pair or Triad

Type P-OS, Type ITC/PLTC, Single Pair or Triad
Specification

Applications
Okonite type P-OS (Pair/Triad - Overall Shield) instrumentation cables are designed for use as instrumentation, process control, and computer cables in ITC non-classified or labeled circuits up to 150 volts and 5 amps (750VA) and in Class 2 or 3 Power-Limited circuits where shielding against external interference is required, but shielding against interference among groups is not required; indoors or outdoors; in wet or dry locations with conductor operating temperatures up to 105°C; in cable trays; in raceways; supported by a messenger wire. Suitable Class I, Division 2, Class II, Division 2, or Class III, Division 2 hazardous locations. Also for use as Power-Limited fire protective signaling cable (FPL) per NEC Code 760.
The overall shield eliminates most of the static interference from the electric field radiated by power cables and other electrical equipment.
For dc service in wet locations, X-Olene® insulation is recommended.

  Product Name
Length
Price (Per FT.)
 

264-10-1101 Type P-OS, Type ITC/PLTC, Single Pair - 22 AWG

FT.
Call 516-472-0650 for pricing

264-15-1101 Type P-OS, Type ITC/PLTC, Single Triad- 22 AWG

FT.
Call 516-472-0650 for pricing

264-10-2201 Type P-OS, Type ITC/PLTC, Single Pair - 20AWG

FT.
Call 516-472-0650 for pricing

264-15-2201 Type P-OS, Type ITC/PLTC, Single Triad- 20 AWG

FT.
Call 516-472-0650 for pricing

264-10-3301 Type P-OS, Type ITC/PLTC, Single Pair - 18 AWG

FT.
Call 516-472-0650 for pricing

264-15-3301 Type P-OS, Type ITC/PLTC, Single Triad- 18 AWG

FT.
Call 516-472-0650 for pricing

264-10-4401 Type P-OS, Type ITC/PLTC, Single Pair - 16 AWG

FT.
Call 516-472-0650 for pricing

264-10-4901 Type P-OS, Type ITC/PLTC, Single Triad- 16 AWG

FT.
Call 516-472-0650 for pricing

Specification

Applications
Okonite type P-OS (Pair/Triad - Overall Shield) instrumentation cables are designed for use as instrumentation, process control, and computer cables in ITC non-classified or labeled circuits up to 150 volts and 5 amps (750VA) and in Class 2 or 3 Power-Limited circuits where shielding against external interference is required, but shielding against interference among groups is not required; indoors or outdoors; in wet or dry locations with conductor operating temperatures up to 105°C; in cable trays; in raceways; supported by a messenger wire. Suitable Class I, Division 2, Class II, Division 2, or Class III, Division 2 hazardous locations. Also for use as Power-Limited fire protective signaling cable (FPL) per NEC Code 760.
The overall shield eliminates most of the static interference from the electric field radiated by power cables and other electrical equipment.
For dc service in wet locations, X-Olene® insulation is recommended.

Details

Specifications
Conductors: Bare soft annealed copper, Class B, 7-strand concentric per ASTM B-8.
Insulation: Flame-retardant Okoseal® (PVC) per UL 13 and UL 2250, 15 mils nominal thickness, 105°C temperature rating.
Color Identification: Pigmented black and white in pairs, black, red and white in triads.
Asembly: Pair or triad assembled with left-hand lay.
Cable Shield: Aluminum/synthetic polymer tape overlapped to provide 100% coverage, and a 7-strand tinned copper drain wire, same size as conductor.
Jacket: Black, flame-retardant, low temperature Okoseal per UL 13 and UL 2250. A rip cord is laid longitudinally under the jacket to facilitate removal.

Classifications
UL Listed as Type ITC/PLTC — Instrumentation Tray Cable/Power Limited Tray Cable for use in accordance with Article 727 and Article 725 of the National Electrical Code.
These cables comply with UL 2250 and UL 13 for PLTC, CL2 and CL3.

Product Features

  • Passes the UL 1581 & IEEE 383-1974 vertical tray flame tests.
  • Sunlight resistant and oil resistant.
  • Individual pairs or triads are color coded for simplified hook-up.
  • Good noise rejection.
  • Excellent weathering characteristics.
  • OSHA Acceptable.
  • Flexible, easy to handle and terminate.
  • Twisted with 100% shield coverage to reduce electromagnetic noise pick-up.
  • Suitable for low temperature installation of -40°C.

Write Your Own Review

You're reviewing: Type P-OS, Type ITC/PLTC, Single Pair or Triad

How do you rate this product? *

 
1 1 star
2 2 star
3 3 star
4 4 star
5 5 star
Quality
Price
Value