SHIELDED TRAY CONTROL CABLE XLP/PVC 600V

SHIELDED TRAY CONTROL CABLE XLP/PVC 600V
Specification

CONDUCTOR:

18 AWG - 16 AWG Class B stranded bare copper per ASTM B-3 and B-8

INSULATION:

Flame-retartdant Cross-linked Polyethylene (XLPE)

JACKET:

Black sunlight and moisture resistant Polyvinyle Chloride (PVC)

TEMPERATURE RANGE:

-30°C to 90°C; (90°C Dry/90°C Wet)

SUNLIGHT RESISTANT: Yes
DIRECT BURIAL: Yes

VOLTAGE RATING: 600V rms, Max


Industry Approvals:

  •  UL Standard 1277 Type TC-ER
  •  NEC Article 336
  •  Passes UL 1685 Flame Test 
  •  Passes IEEE 383 Flame Test (70,000 btu)
  •  ICEA S-73-532 
  •  ICEA S-95-658 (WC70)
  •  EPA 40 CFR, Part 26, Subpart C, heavy metals per Table 1, TCLP method
  Product Name
Length
Price (Per FT.)
 
TRAY CONTROL CABLE XLP/PVC 600V

18/36 PAIRED OVERALL SHIELD (POS) XLP/PVC TC-ER CABLE

FT.
Call 516-472-0650 for pricing
TRAY CONTROL CABLE XLP/PVC 600V

18/24 PAIRED OVERALL SHIELD (POS) XLP/PVC TC-ER CABLE

FT.
Call 516-472-0650 for pricing
TRAY CONTROL CABLE XLP/PVC 600V

18/12 PAIRED OVERALL SHIELD (POS) XLP/PVC TC-ER CABLE

FT.
Call 516-472-0650 for pricing
TRAY CONTROL CABLE XLP/PVC 600V

18/8 PAIRED OVERALL SHIELD (POS) XLP/PVC TC-ER CABLE

FT.
Call 516-472-0650 for pricing
TRAY CONTROL CABLE XLP/PVC 600V

18/4 PAIRED OVERALL SHIELD (POS) XLP/PVC TC-ER CABLE

FT.
Call 516-472-0650 for pricing
TRAY CONTROL CABLE XLP/PVC 600V

18/2 PAIRED OVERALL SHIELD (POS) XLP/PVC TC-ER CABLE

FT.
Call 516-472-0650 for pricing
TRAY CONTROL CABLE XLP/PVC 600V

18/1 PAIRED OVERALL SHIELD (POS) XLP/PVC TC-ER CABLE

FT.
Call 516-472-0650 for pricing
TRAY CONTROL CABLE XLP/PVC 600V

16/36 PAIRED OVERALL SHIELD (POS) XLP/PVC TC-ER CABLE

FT.
Call 516-472-0650 for pricing
TRAY CONTROL CABLE XLP/PVC 600V

16/24 PAIRED OVERALL SHIELD (POS) XLP/PVC TC-ER CABLE

FT.
Call 516-472-0650 for pricing
TRAY CONTROL CABLE XLP/PVC 600V

16/16 PAIRED OVERALL SHIELD (POS) XLP/PVC TC-ER CABLE

FT.
Call 516-472-0650 for pricing
TRAY CONTROL CABLE XLP/PVC 600V

16/12 PAIRED OVERALL SHIELD (POS) XLP/PVC TC-ER CABLE

FT.
Call 516-472-0650 for pricing
TRAY CONTROL CABLE XLP/PVC 600V

16/8 PAIRED OVERALL SHIELD (POS) XLP/PVC TC-ER CABLE

FT.
Call 516-472-0650 for pricing
TRAY CONTROL CABLE XLP/PVC 600V

16/4 PAIRED OVERALL SHIELD (POS) XLP/PVC TC-ER CABLE

FT.
Call 516-472-0650 for pricing
TRAY CONTROL CABLE XLP/PVC 600V

16/2 PAIRED OVERALL SHIELD (POS) XLP/PVC TC-ER CABLE

FT.
Call 516-472-0650 for pricing
TRAY CONTROL CABLE XLP/PVC 600V

16/1 PAIRED OVERALL SHIELD (POS) XLP/PVC TC-ER CABLE

FT.
Call 516-472-0650 for pricing

Specification

CONDUCTOR:

18 AWG - 16 AWG Class B stranded bare copper per ASTM B-3 and B-8

INSULATION:

Flame-retartdant Cross-linked Polyethylene (XLPE)

JACKET:

Black sunlight and moisture resistant Polyvinyle Chloride (PVC)

TEMPERATURE RANGE:

-30°C to 90°C; (90°C Dry/90°C Wet)

SUNLIGHT RESISTANT: Yes
DIRECT BURIAL: Yes

VOLTAGE RATING: 600V rms, Max


Industry Approvals:

  •  UL Standard 1277 Type TC-ER
  •  NEC Article 336
  •  Passes UL 1685 Flame Test 
  •  Passes IEEE 383 Flame Test (70,000 btu)
  •  ICEA S-73-532 
  •  ICEA S-95-658 (WC70)
  •  EPA 40 CFR, Part 26, Subpart C, heavy metals per Table 1, TCLP method

Details

CONDUCTOR:

18 AWG - 16 AWG Class B stranded bare copper per ASTM B-3 and B-8

INSULATION:

Flame-retartdant Cross-linked Polyethylene (XLPE)

JACKET:

Black sunlight and moisture resistant Polyvinyle Chloride (PVC)

TEMPERATURE RANGE:

-30°C to 90°C; (90°C Dry/90°C Wet)

SUNLIGHT RESISTANT: Yes
DIRECT BURIAL: Yes

VOLTAGE RATING: 600V rms, Max


Industry Approvals:

  •  UL Standard 1277 Type TC-ER
  •  NEC Article 336
  •  Passes UL 1685 Flame Test 
  •  Passes IEEE 383 Flame Test (70,000 btu)
  •  ICEA S-73-532 
  •  ICEA S-95-658 (WC70)
  •  EPA 40 CFR, Part 26, Subpart C, heavy metals per Table 1, TCLP method

Video

Write Your Own Review

You're reviewing: SHIELDED TRAY CONTROL CABLE XLP/PVC 600V

How do you rate this product? *

 
1 1 star
2 2 star
3 3 star
4 4 star
5 5 star
Price
Value
Quality