Items in Cart ()

View cart

115-23-3355 4/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 175mils 15KV Power Cable

115-23-3355 4/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 175mils 15KV Power Cable
Roll over image to Zoom

115-23-3355 4/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 175mils 15KV Power Cable

SKU: 115-23-3355

Select a Gauge

115-23-3355 4/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 175mils 15KV Power Cable
Min Length: 1 FT
Max Length: 10000 FT
Price:
Precio habitual
$0.00 /FT
Precio de oferta
$0.00 /FT
Los gastos de envío se calculan en la pantalla de pagos.
Free Shipping: On orders above $1000
La cantidad debe ser 1 o más

Enter the required footage in the quantity box - Cut to one length

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Where are we? 4 Continents 8 Countries

map
garrie

Got any Questions?

Speak with a real person who will go out of their way to help you!

Call Us: 1-516-482-6313Text Us: 1-516-703-3460

Chat

Live Chat: Bottom Right Corner!

Email Us

info@nassaunationalcable.com

Product Information

Specification

115-23-3355 4/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 175mils 15KV Power Cable

Allowable Ampacity for 115-23-3355 4/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TP MV-105 175mils 15KV Power Cable:100 Amps

About:

This power cable is a 4/0 American Wire Gauge (AWG) medium voltage (MV) cable, designed for 15 kilovolt (kV) applications. It is comprised of a single conductor (1C) made from stranded, uncoated copper. The insulation material is Okoguard, and the cable features an Okoclear-TP (Thermoplastic) jacket. The insulation thickness is specified at 175 mils.

Also Known As:

This type of cable may also be known in the industry by specific brand names associated with the Okoguard and Okoclear materials or could be referred to more generically as 15kV medium voltage power cable.

Applications:

 Okoguard shielded Okoclear-TP Type MV-105 power cables are recommended for use as feeder circuits, in electric utility generating stations, for distribution circuits, and for feeders or branch circuits in industrial and commercial installations, where a cable with low smoke/zero halogen characteristics is needed.
 Type MV cables may be installed in wet or dry locations, indoors or outdoors (exposed to sunlight), in any raceway or underground duct, directly buried if installed in a system with a grounding conductor in close proximity that conforms with NEC Section 315.36 and 250.4(A)(5), or messenger supported in industrial establishments and electric utilities.
 May be installed in cable trays where permitted by NEC Section 392 as permitted by
NEC Section 315.32(3).

Standards:

While the specific standards this cable meets can vary, MV-105 designation suggests compliance with certain IEEE (Institute of Electrical and Electronics Engineers) standards for medium voltage cables, which may include requirements for flame resistance, capacity for emergency overload, and resistance to various environmental factors.

Construction:

• Conductor: Uncoated copper compact stranded per ASTM B-496.
• Strand Screen:
 : Extruded semiconducting EPR strand screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639/NEMA WC74 & S-97-682, AEIC CS8, and UL 1072.
• Insulation:
 Meets or exceeds electrical and physical requirements of ICEA S-93-639/NEMA WC74 & S-97-682, AEIC CS8, and UL 1072.
• Insulation Screen:
 Extruded semi conduction EPR insulation screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639/NEMA WC74 & S-97-682, AEIC CS8, and UL 1072.
• Shield:
 5 mil bare copper tape helically applied, with 25% minimum overlap.
• Jacket:
 Meets or exceeds electrical and physical requirements of ICEA S-93-639 for Type I thermoplastic polyolefin jackets.
UL listed as Type MV-105, sunlight resistant and for use in cable tray in accordance with UL 1072.

Features:

 Low smoke/zero halogen jacket.
• 
Okoguard cables meet or exceed all recognized industry standards (UL,
NEMA/ICEA and IEEE).
• 
Triple tandem extruded, all EPR system.
• 
105°C continuous operating temperature.
• 
140°C emergency rating.
• 
250°C short circuit rating
• 
Excellent corona resistance.
• 
Exceptional resistance to “treeing”.
• 
Screens are clean stripping.
• 
Exceptional resistance to moisture.
• 
Resistant to most oils, acids, and alkalis.
• 
UL listed: MV-105, Sunlight Resistant, and Cable Tray Use.
• 
Passes the UL & IEEE 383-1974 Vertical Tray Flame Test.
• 
Sizes 500 kcmil and larger pass FT4/IEEE 1202 Vertical Tray Flame Test.

Specifications:

• Conductor Size AWG: 4/0
• Conduit Size Inches (5):

• Conductor Size mm²: 107.0
• Approx. Dia. over Insulation (in.): 0.87
• Approx. Dia. over Screen (in.): 0.93
• Jacket Thickness (Miles): 80
• Jacket Thickness (mm): 2.03

• Approx. O.D. (Inches): 1.19
• Approx. O.D. (mm): 30.2

• Approx. Net Weight: 1200
• Ampacities (2) Conduit in Air: 330
• Ampacities (3) Underground Duct:
315
• Ampacities (4) Cable Tray:
445
• Part Number: 115-23-3355


*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color

Download PDF Spec Sheet

Reviews

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)
Get in Touch
Live Chat Get replies right away!
Email info@nassaunationalcable.com

Call Us: 1-516-482-6313    Text Us: 1-516-703-3460