ROMEX TYPE NM-B COPPER BUILDING WIRE

ROMEX TYPE NM-B COPPER BUILDING WIRE
Specification

APPLICATIONS

Romex Type NM-B (nonmetallic-sheathed cable) may be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified in the 2011 National Electrical Code. NM-B cable is primarily used in residential wiring as branch circuits for outlets, switches, and other loads. NM-B cable may be run in air voids of masonry block or tile walls where such walls are not wet or damp locations. Voltage rating for NM-B cable is 600 volts.

SPECIFICATIONS

  • ASTM B-3 and B-8
  • UL Standard 83
  • UL Standard 719
  • Federal Specification A-A-59544
  • National Electrical Code, NFPA 70. 2011 Edition
  • RoHS/ REACH

    CONSTRUCTION

    Romex Type NM-B cable is manufactured as 2, 3, or 4 conductor cable, with a bare ground wire. Copper conductors are annealed (soft) copper. Stranded conductors are compressed stranded. Conductor insulation is 90°C-rated polyvinyl chloride (PVC), nylon jacketed. Romex Type NM-B is designed for Easier Pulling, Resulting in Easier installation.

  Product Name
Length
Price (Per FT.)
 
ROMEX TYPE NM-B COPPER BUILDING WIRE

14/4 W/GRND NM-B Romex

FT.
Call 516-472-0650 for pricing
ROMEX TYPE NM-B COPPER BUILDING WIRE

14/3 W/GRND NM-B Romex

FT.
$0.39

ROMEX TYPE NM-B COPPER BUILDING WIRE

14/2 W/GRND NM-B Romex

FT.
$0.24

ROMEX TYPE NM-B COPPER BUILDING WIRE

14-2/2 W/GRND NM-B Romex

FT.
$0.49

ROMEX TYPE NM-B COPPER BUILDING WIRE

12-4 W/GRND NM-B Romex

FT.
Call 516-472-0650 for pricing
ROMEX TYPE NM-B COPPER BUILDING WIRE

12/2 W/GRND NM-B Romex

FT.
$0.36

ROMEX TYPE NM-B COPPER BUILDING WIRE

12/3 W/GRND NM-B Romex

FT.
$0.55

ROMEX TYPE NM-B COPPER BUILDING WIRE

12-2/2 W/GRND NM-B Romex

FT.
$0.69

ROMEX TYPE NM-B COPPER BUILDING WIRE

10/4 W/GRND NM-B Romex

FT.
Call 516-472-0650 for pricing
ROMEX TYPE NM-B COPPER BUILDING WIRE

10/3 W/GRND NM-B Romex

FT.
$0.85

ROMEX TYPE NM-B COPPER BUILDING WIRE

10/2 W/GRND NM-B Romex

FT.
$0.64

ROMEX TYPE NM-B COPPER BUILDING WIRE

8/3 W/GRND NM-B Romex

FT.
$1.42

ROMEX TYPE NM-B COPPER BUILDING WIRE

8/2 W/GRND NM-B Romex

FT.
$0.95

ROMEX TYPE NM-B COPPER BUILDING WIRE

6/3 W/GRND NM-B Romex

FT.
$2.11

ROMEX TYPE NM-B COPPER BUILDING WIRE

6/2 W/GRND NM-B Romex

FT.
$1.29

ROMEX TYPE NM-B COPPER BUILDING WIRE

4/3 W/GRND NM-B Romex

FT.
$4.37

ROMEX TYPE NM-B COPPER BUILDING WIRE

2/3 W/GRND NM-B Romex

FT.
$6.61

Specification

APPLICATIONS

Romex Type NM-B (nonmetallic-sheathed cable) may be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified in the 2011 National Electrical Code. NM-B cable is primarily used in residential wiring as branch circuits for outlets, switches, and other loads. NM-B cable may be run in air voids of masonry block or tile walls where such walls are not wet or damp locations. Voltage rating for NM-B cable is 600 volts.

SPECIFICATIONS

  • ASTM B-3 and B-8
  • UL Standard 83
  • UL Standard 719
  • Federal Specification A-A-59544
  • National Electrical Code, NFPA 70. 2011 Edition
  • RoHS/ REACH

    CONSTRUCTION

    Romex Type NM-B cable is manufactured as 2, 3, or 4 conductor cable, with a bare ground wire. Copper conductors are annealed (soft) copper. Stranded conductors are compressed stranded. Conductor insulation is 90°C-rated polyvinyl chloride (PVC), nylon jacketed. Romex Type NM-B is designed for Easier Pulling, Resulting in Easier installation.

Details

APPLICATIONS

Romex Type NM-B (nonmetallic-sheathed cable) may be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified in the 2011 National Electrical Code. NM-B cable is primarily used in residential wiring as branch circuits for outlets, switches, and other loads. NM-B cable may be run in air voids of masonry block or tile walls where such walls are not wet or damp locations. Voltage rating for NM-B cable is 600 volts.

SPECIFICATIONS

  • ASTM B-3 and B-8
  • UL Standard 83
  • UL Standard 719
  • Federal Specification A-A-59544
  • National Electrical Code, NFPA 70. 2011 Edition
  • RoHS/ REACH

    CONSTRUCTION

    Romex Type NM-B cable is manufactured as 2, 3, or 4 conductor cable, with a bare ground wire. Copper conductors are annealed (soft) copper. Stranded conductors are compressed stranded. Conductor insulation is 90°C-rated polyvinyl chloride (PVC), nylon jacketed. Romex Type NM-B is designed for Easier Pulling, Resulting in Easier installation.

Video

Write Your Own Review

You're reviewing: ROMEX TYPE NM-B COPPER BUILDING WIRE

How do you rate this product? *

 
1 1 star
2 2 star
3 3 star
4 4 star
5 5 star
Quality